FireCADCalc

Shrink Fit Heating Temperature

Temperature to heat a hub (or cool a shaft) so it slides on for a shrink fit, from the interference, assembly clearance, diameter and expansion coefficient.

Inputs

Examples: 50 mm steel, 40 µm + 25 µm, 30 °C300 mm steel ring, 0.3 mm + 0.1 mmBronze bush 80 mm cooled: 30 µm + 20 µm, α 18e-6

Results

Linear expansion with a constant coefficient. Heat evenly; bearings, tempered and hardened parts have temperature limits: check the hub temperature against the maker's limit.

Temperature rise needed34.722K
Heating temperature of the hub54.722°C
Or: cooling temperature of the shaft-14.722°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 50 mm steel, 40 µm + 25 µm, 30 °C. The inputs, in the units selected above:

InputValue
Diametral interference40.000 µm
Assembly clearance wanted25.000 µm
Fit diameter50.000 mm
Expansion coefficient12.000 µm/(m·K)
Ambient temperature30.000 °C

Applying the formula below gives:

ResultValue
Temperature rise needed108.33 K
Heating temperature of the hub138.33 °C
Or: cooling temperature of the shaft-78.333 °C

Open this example in the calculator and change any input.

Formula

\(\Delta T = \frac{\delta + c}{\alpha\, d}, \quad T_h = T_a + \Delta T, \quad T_c = T_a - \Delta T\)

Variables

Symbol Meaning SI unit
\(\delta\) Diametral interference m
\(c\) Assembly clearance wanted m
\(d\) Fit diameter m
\(\alpha\) Expansion coefficient 1/K
\(T_a\) Ambient temperature K
\(\Delta T\) Temperature rise needed K
\(T_h\) Heating temperature of the hub K
\(T_c\) Or: cooling temperature of the shaft K

Method and standards

Linear thermal expansion.

Where it is used

  • Fitting bearings, gears and couplings.
  • Maintenance planning.

Common mistakes

  • Forgetting clearance.
  • Overheating bearings or hardened parts.

Assumptions and limits

  • Constant α. At cryogenic temperatures α falls, so a cooling result below about −78 °C (dry ice) is optimistic; the page warns, and below liquid nitrogen (about −196 °C) no cooling temperature is shown.
  • The hub temperature is not checked against a limit: keep it below the maker's limit for bearings, tempered and hardened parts.

References

  • Linear thermal expansion Δd = α d ΔT

Questions and answers

How hot for a 50 mm steel hub with 40 µm interference and 25 µm clearance?

A 108 K rise: heat the hub to about 138 °C.

Why add clearance?

The part cools while it is being pushed on; without clearance it seizes half-way.

Can I cool the shaft?

Yes, with dry ice or liquid nitrogen for small rises.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.