Worked example
Example: 50 mm steel, 40 µm + 25 µm, 30 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Diametral interference | 40.000 µm |
| Assembly clearance wanted | 25.000 µm |
| Fit diameter | 50.000 mm |
| Expansion coefficient | 12.000 µm/(m·K) |
| Ambient temperature | 30.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Temperature rise needed | 108.33 K |
| Heating temperature of the hub | 138.33 °C |
| Or: cooling temperature of the shaft | -78.333 °C |
Open this example in the calculator and change any input.
Formula
\(\Delta T = \frac{\delta + c}{\alpha\, d}, \quad T_h = T_a + \Delta T, \quad T_c = T_a - \Delta T\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\delta\) | Diametral interference | m |
| \(c\) | Assembly clearance wanted | m |
| \(d\) | Fit diameter | m |
| \(\alpha\) | Expansion coefficient | 1/K |
| \(T_a\) | Ambient temperature | K |
| \(\Delta T\) | Temperature rise needed | K |
| \(T_h\) | Heating temperature of the hub | K |
| \(T_c\) | Or: cooling temperature of the shaft | K |
Method and standards
Linear thermal expansion.
Where it is used
- Fitting bearings, gears and couplings.
- Maintenance planning.
Common mistakes
- Forgetting clearance.
- Overheating bearings or hardened parts.
Assumptions and limits
- Constant α. At cryogenic temperatures α falls, so a cooling result below about −78 °C (dry ice) is optimistic; the page warns, and below liquid nitrogen (about −196 °C) no cooling temperature is shown.
- The hub temperature is not checked against a limit: keep it below the maker's limit for bearings, tempered and hardened parts.
References
- Linear thermal expansion Δd = α d ΔT
Questions and answers
How hot for a 50 mm steel hub with 40 µm interference and 25 µm clearance?
A 108 K rise: heat the hub to about 138 °C.
Why add clearance?
The part cools while it is being pushed on; without clearance it seizes half-way.
Can I cool the shaft?
Yes, with dry ice or liquid nitrogen for small rises.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.