FireCADCalc

Flange Coupling Bolt Shear from Torque

Shear stress in the bolts of a rigid flange coupling from the torque, number of bolts and pitch circle, with the bolt diameter needed and the shaft torque capacity.

Inputs

Examples: 2 kN·m, six 12 mm bolts on 160 mm15 kN·m, eight 20 mm on 300 mm400 N·m, four 10 mm on 100 mm

Results

Fitted bolts in shear, load shared equally. With clearance bolts the torque passes by friction from the bolt preload instead.

Force on each bolt4.1667kN
Shear stress in the bolts36.841MPa
Bolt diameter needed9.4032mm
Torque the bolts carry at the allowable stress3,257.2N·m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 2 kN·m, six 12 mm bolts on 160 mm. The inputs, in the units selected above:

InputValue
Torque transmitted2,000.0 N·m
Number of bolts6.0000 -
Bolt pitch circle diameter160.00 mm
Bolt diameter (shank in shear)12.000 mm
Allowable shear stress of the bolts60.000 MPa

Applying the formula below gives:

ResultValue
Force on each bolt4.1667 kN
Shear stress in the bolts36.841 MPa
Bolt diameter needed9.4032 mm
Torque the bolts carry at the allowable stress3,257.2 N·m

Open this example in the calculator and change any input.

Formula

\(F_b = \frac{2T}{n D_b}, \quad \tau = \frac{F_b}{\pi d^2/4}, \quad T_{max} = n\, \frac{\pi d^2}{4}\, \tau_a\, \frac{D_b}{2}\)

Variables

Symbol Meaning SI unit
\(T\) Torque transmitted N·m
\(n\) Number of bolts -
\(D_b\) Bolt pitch circle diameter m
\(d\) Bolt diameter (shank in shear) m
\(\tau_a\) Allowable shear stress of the bolts Pa
\(F_b\) Force on each bolt N
\(\tau\) Shear stress in the bolts Pa
\(d_{min}\) Bolt diameter needed m
\(T_{max}\) Torque the bolts carry at the allowable stress N·m

Method and standards

Torque shared equally by the bolts.

Where it is used

  • Coupling selection and checks.
  • Machine design examinations.

Common mistakes

  • Diameter instead of radius.
  • Using the thread root for fitted bolts.

Assumptions and limits

  • Equal sharing. A shear stress above the allowable is flagged.
  • Bearing (crushing) of the bolts on the flange and the flange and hub strength are not checked.

References

  • Rigid flange coupling
  • fitted bolts in shear (textbook machine design)

Questions and answers

Six 12 mm bolts on a 160 mm circle carrying 2 kN·m?

4167 N per bolt, 36.8 MPa.

Fitted or clearance bolts?

Fitted (reamed) bolts work in shear; clearance bolts rely on friction.

Why a larger pitch circle?

It lowers the bolt force for the same torque.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.