Worked example
Example: Flat belt: 2 kN, mu 0.3, 165°, 0.5 kg/m, 20 m/s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Allowable belt tension | 2.0000 kN |
| Coefficient of friction | 0.30000 - |
| Angle of wrap on the smaller pulley | 165.00 ° |
| Belt type | Flat belt |
| V-groove included angle | 40.000 ° |
| Belt mass per metre | 0.50000 kg/m |
| Belt speed | 20.000 m/s |
Applying the formula below gives:
| Result | Value |
|---|---|
| Tension ratio e^(μθ) (μ / sin β for a V-belt) | 2.3725 |
| Centrifugal tension m v² | 0.20000 kN |
| Tight-side tension T_max − T_c | 1.8000 kN |
| Slack-side tension | 0.75870 kN |
| Power transmitted (T₁ − T₂) v | 20.826 kW |
| Speed for maximum power √(T_max / 3m) | 36.515 m/s |
| Maximum power (at that speed) | 28.165 kW |
Open this example in the calculator and change any input.
Formula
\(\frac{T_1 - T_c}{T_2 - T_c} = e^{\mu_e \theta}\ \to\ \frac{T_1}{T_2} = e^{\mu_e \theta}\ (T_1 = T_{max} - T_c)\)
\(T_c = m v^2, \quad P = (T_1 - T_2)\, v, \quad \mu_e = \frac{\mu}{\sin\beta}\)
\(v_{opt} = \sqrt{\frac{T_{max}}{3m}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_{max}\) | Allowable belt tension | N |
| \(\mu\) | Coefficient of friction | - |
| \(\theta\) | Angle of wrap on the smaller pulley | rad |
| \(\text{belt}\) | Belt type | - |
| \(2\beta\) | V-groove included angle | rad |
| \(m\) | Belt mass per metre | kg/m |
| \(v\) | Belt speed | m/s |
| \(T_1/T_2\) | Tension ratio e^(μθ) (μ / sin β for a V-belt) | - |
| \(T_c\) | Centrifugal tension m v² | N |
| \(T_1\) | Tight-side tension T_max − T_c | N |
| \(T_2\) | Slack-side tension | N |
| \(P\) | Power transmitted (T₁ − T₂) v | W |
| \(v_{opt}\) | Speed for maximum power √(T_max / 3m) | m/s |
| \(P_{max}\) | Maximum power (at that speed) | W |
Method and standards
Capstan friction equation with centrifugal tension subtracted from the allowable tension.
Where it is used
- Fan and pump belt drives.
- Checking belt slip.
- Machine design examinations.
Common mistakes
- Wrap angle in degrees in the exponent.
- Using the full groove angle instead of half.
- Ignoring centrifugal tension.
Assumptions and limits
- Steady drive; creep neglected.
- No service factor: P is the friction-limited capacity at the allowable tension. Divide it by the drive's service factor (from the belt maker) for the rated power.
References
- Euler–Eytelwein (capstan) equation
- Shigley's Mechanical Engineering Design
- ch. 17
Questions and answers
What does a flat belt carry: 2 kN allowable, μ 0.3, 165° wrap, 0.5 kg/m, 20 m/s?
Centrifugal tension 200 N leaves T₁ = 1800 N; T₁/T₂ = 2.37, T₂ = 759 N; power 20.8 kW.
What speed gives the most power?
v = √(T_max/3m) = 36.5 m/s, giving 28.2 kW.
Why do V-belts grip better?
The wedge multiplies friction by 1/sin(β): a 40° groove makes μ 0.25 act like 0.73.