Worked example
Example: Illustrative: 2 x 1 m panels facing each other 1 m apart. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Geometry | Aligned parallel rectangles X × Y, spaced Z apart |
| Side X (common edge for perpendicular) | 2.0000 m |
| Side Y (width of surface i) | 1.0000 m |
| Spacing Z (parallel) or height of surface j (perpendicular) | 1.0000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| View factor from surface i to j | 0.28588 |
| View factor from j to i | 0.28588 |
| Area of surface i | 2.0000 m² |
| Area of surface j | 2.0000 m² |
Open this example in the calculator and change any input.
Formula
\(\text{parallel: } F_{ij} = \frac{2}{\pi\bar X\bar Y}\left\{\ln\left[\frac{(1 + \bar X^2)(1 + \bar Y^2)}{1 + \bar X^2 + \bar Y^2}\right]^{1/2} + \bar X\sqrt{1 + \bar Y^2}\tan^{-1}\frac{\bar X}{\sqrt{1 + \bar Y^2}} + \bar Y\sqrt{1 + \bar X^2}\tan^{-1}\frac{\bar Y}{\sqrt{1 + \bar X^2}} - \bar X\tan^{-1}\bar X - \bar Y\tan^{-1}\bar Y\right\}\)
\(A_iF_{ij} = A_jF_{ji}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{geometry}\) | Geometry | - |
| \(X\) | Side X (common edge for perpendicular) | m |
| \(Y\) | Side Y (width of surface i) | m |
| \(Z\) | Spacing Z (parallel) or height of surface j (perpendicular) | m |
| \(F_{ij}\) | View factor from surface i to j | - |
| \(F_{ji}\) | View factor from j to i | - |
| \(A_i\) | Area of surface i | m² |
| \(A_j\) | Area of surface j | m² |
Method and standards
Diffuse-surface view factors.
Where it is used
- Furnace and kiln wall exchange, heater design.
- Radiant panels, solar and building radiation.
Common mistakes
- Swapping the surfaces in the perpendicular case.
- Forgetting reciprocity for the reverse factor.
Assumptions and limits
- Diffuse, flat surfaces; no obstruction between them.
References
- Analytical view factors for aligned parallel and perpendicular rectangles
Questions and answers
What does a view factor of 0.2 mean?
One fifth of the diffuse radiation leaving surface i strikes surface j directly; the rest goes elsewhere in the enclosure.
How do I handle an offset rectangle?
Use view factor algebra: build the surfaces from rectangles that share the formula's geometry and add or subtract the factors.
What do the defaults represent?
An illustrative pair of 2 × 1 m panels facing each other 1 m apart.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Incropera, DeWitt, Bergman and Lavine, Fundamentals of Heat and Mass Transfer, 6th ed. (Wiley, 2007), Table 13.2