FireCADCalc

Heat Pipe Capillary Limit (Maximum Heat Transport)

Maximum heat a wicked heat pipe can carry before its wick dries out, from the working fluid, wick permeability, area and pore radius, length and tilt.

Inputs

Examples: Illustrative copper-water heat pipe, horizontalSame pipe, evaporator 30 degrees upAmmonia groove pipe for spacecraft

Accepted: 100 to 20,000 kg/m³
Accepted: 0.1 to 1,000 mN/m
Accepted: 10 to 10,000 kJ/kg
Accepted: 0.001 to 1,000 mPa·s
Accepted: 1E-10 to 1 mm²
Accepted: 0.001 to 100,000 mm²
Accepted: 1E-4 to 10 mm
Accepted: 1 to 100,000 mm
Accepted: 1 to 100,000 mm
Accepted: -90 to 90 °

Results

The wick's capillary pressure 2σ/r_eff must drive the condensed liquid back to the evaporator against its viscous drop (Darcy's law, μ_lṁL_eff/(ρ_lKA_w)) and any adverse gravity head ρ_lgL_t sin ψ. Equating them gives the capillary limit Q = ρ_lσh_fg/μ_l·(KA_w/L_eff)·(2/r_eff − ρ_lgL_t sin ψ/σ) (Chi). The vapour pressure drop is neglected, which is reasonable for moderate lengths. Water has the highest figure of merit ρσh_fg/μ near 100–200 °C; sintered wicks have small pores (high pumping) but low permeability.

Maximum capillary pressure 2σ/r2,560.0Pa
Adverse gravity head1,673.3Pa
Capillary limit64.773W
Liquid flow at the limit0.028040g/s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative copper-water heat pipe, horizontal. The inputs, in the units selected above:

InputValue
Liquid density975.00 kg/m³
Surface tension64.000 mN/m
Latent heat2,310.0 kJ/kg
Liquid viscosity0.37000 mPa·s
Wick permeability1.5000e-04 mm²
Wick cross-sectional area20.000 mm²
Effective pore radius0.050000 mm
Effective length (L_a + (L_e + L_c)/2)250.00 mm
Total length350.00 mm
Tilt (evaporator above condenser positive)0 °

Applying the formula below gives:

ResultValue
Maximum capillary pressure 2σ/r2,560.0 Pa
Adverse gravity head0 Pa
Capillary limit187.00 W
Liquid flow at the limit0.080951 g/s

Open this example in the calculator and change any input.

Formula

\(\dot Q_{max} = \frac{\rho_l\sigma h_{fg}}{\mu_l}\frac{KA_w}{L_{eff}}\left(\frac{2}{r_{eff}} - \frac{\rho_lgL_t\sin\psi}{\sigma}\right)\)

Variables

Symbol Meaning SI unit
\(\rho_l\) Liquid density kg/m³
\(\sigma\) Surface tension N/m
\(h_{fg}\) Latent heat J/kg
\(\mu_l\) Liquid viscosity Pa·s
\(K\) Wick permeability m²
\(A_w\) Wick cross-sectional area m²
\(r_{eff}\) Effective pore radius m
\(L_{eff}\) Effective length (L_a + (L_e + L_c)/2) m
\(L_t\) Total length m
\(\psi\) Tilt (evaporator above condenser positive) rad
\(\Delta p_{c}\) Maximum capillary pressure 2σ/r Pa
\(\Delta p_g\) Adverse gravity head Pa
\(\dot Q_{max}\) Capillary limit W
\(\dot m\) Liquid flow at the limit kg/s

Method and standards

Capillary limit.

Where it is used

  • Electronics and spacecraft thermal design.
  • Choosing wick and fluid for heat pipes.

Common mistakes

  • Ignoring tilt in the application orientation.
  • Using the geometric pore size instead of the effective radius.

Assumptions and limits

  • Vapour pressure drop neglected; uniform wick; properties at the operating temperature.

References

  • Capillary limit of wicked heat pipes

Questions and answers

Why does tilting reduce the limit?

With the evaporator above the condenser, the wick must also lift the liquid against gravity.

What other limits exist?

Sonic, entrainment, boiling and viscous limits; the lowest one governs.

What do the defaults represent?

An illustrative copper–water heat pipe with a sintered wick (K = 1.5 × 10⁻¹⁰ m², r = 50 µm, 20 mm² wick area), horizontal, 350 mm long.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Faghri, Heat Pipe Science and Technology (Taylor and Francis, 1995); Chi, Heat Pipe Theory and Practice (Hemisphere, 1976)

Related calculators