FireCADCalc

Radiation in a Two-Surface Gray Enclosure: Cylinders, Spheres, Plates

Net radiation between two diffuse gray surfaces forming an enclosure (concentric cylinders or spheres, parallel plates or a general pair) by the radiosity network.

Inputs

Examples: Illustrative: pipe at 300 C (eps 0.8) in a jacket at 50 C (eps 0.3), r1/r2 0.6Cryogenic sphere: inner 0.5 m2 at 77 K, outer at 300 K, r1/r2 0.8, eps 0.05Large parallel plates 800 and 400 C, eps 0.85 and 0.6General: A1/A2 0.4, F12 0.9, 500 and 300 K

Accepted: 1E-6 to 100,000 m²
Accepted: 0 to 1
Accepted: 0.001 to 1
Accepted: 1 to 100 %
Accepted: 1 to 100 %
Accepted: -272.15 to 2,726.8 °C
Accepted: -272.15 to 2,726.8 °C

Results

Radiosity network of two diffuse gray surfaces: q = σA₁(T₁⁴ − T₂⁴)/[(1 − ε₁)/ε₁ + 1/F₁₂ + (1 − ε₂)/ε₂ · A₁/A₂]. For cylinders the areas are per unit length (A₁ = 2πr₁L).

Net radiation from 1 to 234.486kW
Net flux on surface 134,486W/m²
Effective emissivity q/(σA₁(T₁⁴ − T₂⁴))0.54255
Area ratio used1.0000
Radiosity of surface 169,120W/m²
Radiosity of surface 234,634W/m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: pipe at 300 C (eps 0.8) in a jacket at 50 C (eps 0.3), r1/r2 0.6. The inputs, in the units selected above:

InputValue
GeometryLong concentric cylinders
Area of the inner (or first) surface1.0000 m²
Radius ratio (cylinders, spheres) or area ratio (general)0.60000 -
View factor from 1 to 2 (general only)1.0000 -
Emissivity of surface 180.000 %
Emissivity of surface 230.000 %
Temperature of surface 1300.00 °C
Temperature of surface 250.000 °C

Applying the formula below gives:

ResultValue
Net radiation from 1 to 22.0757 kW
Net flux on surface 12,075.7 W/m²
Effective emissivity q/(σA₁(T₁⁴ − T₂⁴))0.37736
Area ratio used0.60000
Radiosity of surface 15,600.1 W/m²
Radiosity of surface 23,524.4 W/m²

Open this example in the calculator and change any input.

Formula

\(q_{12} = \frac{\sigma A_1(T_1^4 - T_2^4)}{\frac{1 - \varepsilon_1}{\varepsilon_1} + \frac{1}{F_{12}} + \frac{1 - \varepsilon_2}{\varepsilon_2}\frac{A_1}{A_2}}, \quad \frac{A_1}{A_2} = \frac{r_1}{r_2}\ \text{(cylinders)}, \ \left(\frac{r_1}{r_2}\right)^2\ \text{(spheres)}\)

Variables

Symbol Meaning SI unit
\(\text{geometry}\) Geometry -
\(A_1\) Area of the inner (or first) surface m²
\(r_1/r_2\ \text{or}\ A_1/A_2\) Radius ratio (cylinders, spheres) or area ratio (general) -
\(F_{12}\) View factor from 1 to 2 (general only) -
\(\varepsilon_1\) Emissivity of surface 1 -
\(\varepsilon_2\) Emissivity of surface 2 -
\(T_1\) Temperature of surface 1 K
\(T_2\) Temperature of surface 2 K
\(q_{12}\) Net radiation from 1 to 2 W
\(q_{12}/A_1\) Net flux on surface 1 W/m²
\(\varepsilon_{eff}\) Effective emissivity q/(σA₁(T₁⁴ − T₂⁴)) -
\(A_1/A_2\) Area ratio used -
\(J_1\) Radiosity of surface 1 W/m²
\(J_2\) Radiosity of surface 2 W/m²

Method and standards

Radiosity network for a two-surface gray enclosure.

Where it is used

  • Jacketed and insulated pipes, double-walled vessels and cryostats.
  • Thermocouple wells and furnace tubes.

Common mistakes

  • Using the parallel-plate formula for cylinders.
  • Forgetting that the inner surface must be convex (F₁₁ = 0).

Assumptions and limits

  • Diffuse gray surfaces, uniform temperatures and radiosities, non-participating gas.

References

  • Two-surface radiosity network for diffuse gray surfaces

Questions and answers

Why does the outer surface emissivity matter less for a small inner body?

Its resistance is scaled by A₁/A₂; when the outer surface is much larger it behaves almost like a black cavity.

Can I use it for a pipe inside a jacket?

Yes: choose concentric cylinders, enter the pipe's area per metre and the radius ratio of pipe to jacket.

What do the defaults represent?

An illustrative pipe at 300 °C (ε 0.8) inside a jacket at 50 °C (ε 0.3) with a radius ratio of 0.6, per square metre of pipe surface.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Incropera, DeWitt, Bergman and Lavine, Fundamentals of Heat and Mass Transfer, 6th ed. (Wiley, 2007), sec. 13.3, Table 13.3

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.