FireCADCalc

Dispersion Number from a Tracer Test

Dispersion number d from the mean and variance of a tracer curve (open and closed vessel), equivalent tanks in series and the coefficient of dispersion.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Baffled tank, broad curvePoorly baffled contact tank

Accepted: 0.00027778 to 277.78 h
Accepted: 1E-6 to 100,000,000
Accepted: 0.0864 to 4,320,000 m³/d
Accepted: 1 to 1,000,000 m³
Accepted: 1 to 10,000 m

Results

Dispersion numbers below 0.05 mean low dispersion (close to plug flow); above 0.25 the basin behaves more like a mixed tank. The coefficient of dispersion uses the mean velocity along the actual flow path, L/τ.

Theoretical detention time1.0000h
Normalised mean time0.55000
Normalised variance0.25000
Dispersion number (open vessel, σθ² = 2d)0.12500
Dispersion number (closed vessel)0.14641
Equivalent tanks in series4.0000
Coefficient of dispersion (closed d)0.016268m²/s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Baffled tank, broad curve. The inputs, in the units selected above:

InputValue
Mean residence time of the tracer curve1.6000 h
Variance of the tracer curve (min²)600.00 -
Flow through the basin2,400.0 m³/d
Basin volume200.00 m³
Flow path length60.000 m

Applying the formula below gives:

ResultValue
Theoretical detention time2.0000 h
Normalised mean time0.80000
Normalised variance0.041667
Dispersion number (open vessel, σθ² = 2d)0.020833
Dispersion number (closed vessel)0.021286
Equivalent tanks in series24.000
Coefficient of dispersion (closed d)0.010643 m²/s

Open this example in the calculator and change any input.

Formula

\(\sigma_\theta^2 = \frac{\sigma^2}{\tau^2}, \quad d_{open} = \frac{\sigma_\theta^2}{2}, \quad \sigma_\theta^2 = 2d - 2d^2\left(1 - e^{-1/d}\right), \quad N = \frac{1}{\sigma_\theta^2}, \quad D = d\frac{L^2}{\tau}\)

Variables

Symbol Meaning SI unit
\(\bar t\) Mean residence time of the tracer curve s
\(\sigma^2\) Variance of the tracer curve (min²) -
\(Q\) Flow through the basin m³/s
\(V\) Basin volume m³
\(L\) Flow path length m
\(\tau\) Theoretical detention time s
\(\bar\theta\) Normalised mean time -
\(\sigma_\theta^2\) Normalised variance -
\(d_{open}\) Dispersion number (open vessel, σθ² = 2d) -
\(d_{closed}\) Dispersion number (closed vessel) -
\(N\) Equivalent tanks in series -
\(D\) Coefficient of dispersion (closed d) m²/s

Method and standards

Dispersion model of non-ideal flow.

Where it is used

  • Contact basin and reactor hydraulic assessment.
  • Checking baffle effectiveness.

Common mistakes

  • Entering the variance in h² while τ is in minutes.
  • Using one channel length for a serpentine basin.

Assumptions and limits

  • Pulse tracer; first and second moments from a complete curve.

Questions and answers

Which dispersion number should I use?

For small values (d < 0.01) the open and closed answers agree; for larger values the closed-vessel relation, which accounts for the inlet and outlet boundaries, is more appropriate for basins.

What do the defaults represent?

An illustrative case: Baffled tank, broad curve. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Metcalf and Eddy (Tchobanoglous, Stensel, Tsuchihashi and Burton), Wastewater Engineering: Treatment and Resource Recovery, 5th ed. (McGraw-Hill, 2014), Appendix I, eqs. I-7 to I-9 and Example I-1; Levenspiel's closed-vessel relation

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.