Constructed Wetland (Reed Bed) Area by Kickuth

Bed area of a horizontal subsurface-flow constructed wetland to cut BOD from inlet to outlet concentration by the Kickuth equation, with area per person.

Inputs

Examples: Illustrative 150-person reed bedPolishing STP effluentSchool, 400 persons

Accepted: 0.0864 to 86,400 m³/d
Accepted: 1 to 2,000 mg/L
Accepted: 0.1 to 1,000 mg/L
Accepted: 0.01 to 1 m/d
Accepted: 0 to 1,000,000

Results

Kickuth's equation A = Q(ln C_i − ln C_o)/K_BOD treats BOD removal as first order on the bed area, with K_BOD about 0.1 m/day for horizontal subsurface-flow reed beds treating settled domestic sewage. Pre-treat (septic or settling tank) to remove solids that would clog the gravel. Typical results are 2–5 m² per person for secondary treatment; check the cross-section for hydraulic capacity through the gravel too.

Bed area592.85m²
Area per person1.4821m²
Hydraulic loading42.169mm/d

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 150-person reed bed. The inputs, in the units selected above:

InputValue
Daily flow20.000 m³/d
Inlet BOD150.00 mg/L
Outlet BOD wanted20.000 mg/L
Area rate constant0.10000 m/d
Population served (0 = skip)150.00 -

Applying the formula below gives:

ResultValue
Bed area402.98 m²
Area per person2.6865 m²
Hydraulic loading49.630 mm/d

Open this example in the calculator and change any input.

Formula

\(A = \frac{Q\left(\ln C_i - \ln C_o\right)}{K_{BOD}}\)

Variables

Symbol Meaning SI unit
\(Q\) Daily flow m³/s
\(C_i\) Inlet BOD kg/m³
\(C_o\) Outlet BOD wanted kg/m³
\(K_{BOD}\) Area rate constant m/s
\(N\) Population served (0 = skip) -
\(A\) Bed area m²
\(A/N\) Area per person m²
\(q_h\) Hydraulic loading m/s

Method and standards

Constructed wetland.

Where it is used

  • Small communities, resorts and schools.
  • Polishing STP effluent.

Common mistakes

  • Using raw sewage BOD without pre-treatment.
  • Using one K value for all climates.

Assumptions and limits

  • Horizontal subsurface flow; first-order BOD removal.

References

  • Kickuth horizontal-flow constructed wetland sizing equation

Questions and answers

How much reed bed for 20 m³/day from 150 to 20 mg/L BOD?

About 400 m², or 2.7 m² per person for 150 people.

Why pre-treat?

Suspended solids clog the gravel and stop subsurface flow.

What do the defaults represent?

An illustrative 20 m³/day of settled sewage from 150 people, BOD 150 mg/L to 20 mg/L, K = 0.1 m/day.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.