FireCADCalc

Air Stripping Tower for Ammonia: Diameter, HTU, NTU and Height

Air-to-water ratio from the stripping factor, liquid and gas loading from the packing pressure-drop correlation, tower diameter, HTU, NTU and packing height.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Stripping factor 2, same waterSmall TCE stripper, H 550 atm, S 4

Accepted: 0.864 to 432,000 m³/d
Accepted: 0.1 to 1,000 mg/L
Accepted: 0.001 to 1,000 mg/L
Accepted: 0.01 to 1,000
Accepted: 0.49346 to 1.9738 atm
Accepted: 1.05 to 20
Accepted: 0.0001 to 1 1/s
Accepted: 0.001 to 5
Accepted: 1 to 500
Accepted: 0.5 to 2 kg/m³
Accepted: 900 to 1,100 kg/m³
Accepted: 0.1 to 5 cP

Results

Read the ordinate from the generalised pressure-drop chart at the abscissa shown and the chosen pressure drop. Add 2-3 m to the packing height for the plenum and gas outlet.

Air-to-water ratio by volume3,555.3m³/m³
Abscissa (L'/G')(ρ_G/ρ_L)^½0.008104
Gas loading4.2429kg/(m²·s)
Liquid loading0.98942kg/(m²·s)
Tower diameter7.7117m
Height of a transfer unit0.079296m
Number of transfer units6.0408
Packing height0.47902m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Stripping factor 2, same water. The inputs, in the units selected above:

InputValue
Water flow4,000.0 m³/d
Inlet ammonia40.000 mg/L
Outlet ammonia1.0000 mg/L
Henry's constant (atm)0.75000 -
Total pressure1.0000 atm
Stripping factor2.0000 -
Overall transfer coefficient0.012500 1/s
Ordinate from the pressure-drop chart0.30000 -
Packing factor20.000 -
Air density1.2040 kg/m³
Water density998.20 kg/m³
Water viscosity1.0020 cP

Applying the formula below gives:

ResultValue
Air-to-water ratio by volume3,555.3 m³/m³
Abscissa (L'/G')(ρ_G/ρ_L)^½0.008104
Gas loading4.2429 kg/(m²·s)
Liquid loading0.98942 kg/(m²·s)
Tower diameter7.7117 m
Height of a transfer unit0.079296 m
Number of transfer units6.0408
Packing height0.47902 m

Open this example in the calculator and change any input.

Formula

\(\frac{G}{L} = \frac{SP_T}{H}, \quad G' = \left[\frac{Y\rho_G(\rho_L - \rho_G)}{C_f\mu_L^{0.1}}\right]^{1/2}, \quad A = \frac{Q\rho_L}{L'}\)

\(HTU = \frac{Q}{K_LaA}, \quad NTU = \frac{S}{S - 1}\ln\frac{(C_o/C_e)(S - 1) + 1}{S}, \quad Z = HTU\cdot NTU\)

Variables

Symbol Meaning SI unit
\(Q\) Water flow m³/s
\(C_o\) Inlet ammonia kg/m³
\(C_e\) Outlet ammonia kg/m³
\(H\) Henry's constant (atm) -
\(P_T\) Total pressure Pa
\(S\) Stripping factor -
\(K_La\) Overall transfer coefficient 1/s
\(Y\) Ordinate from the pressure-drop chart -
\(C_f\) Packing factor -
\(\rho_G\) Air density kg/m³
\(\rho_L\) Water density kg/m³
\(\mu_L\) Water viscosity Pa·s
\(G/L\) Air-to-water ratio by volume m³/m³
\(X\) Abscissa (L'/G')(ρ_G/ρ_L)^½ -
\(G'\) Gas loading kg/(m²·s)
\(L'\) Liquid loading kg/(m²·s)
\(D\) Tower diameter m
\(HTU\) Height of a transfer unit m
\(NTU\) Number of transfer units -
\(Z\) Packing height m

Method and standards

Packed tower stripping design (HTU-NTU method).

Where it is used

  • Ammonia and VOC stripping.
  • Sizing packed towers from pilot K_La.

Common mistakes

  • Using the area from the gas loading.
  • Taking Henry's constant at the wrong temperature.

Assumptions and limits

  • Dilute, isothermal; K_La from pilot data or a correlation.

Questions and answers

Why is ammonia hard to strip?

Its Henry's constant is low (0.75 atm at 20 °C) and only free NH₃ strips, so the pH must be raised to about 11 and very large air flows are needed.

What do the defaults represent?

An illustrative case: Stripping factor 2, same water. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Metcalf and Eddy (Tchobanoglous, Stensel, Tsuchihashi and Burton), Wastewater Engineering: Treatment and Resource Recovery, 5th ed. (McGraw-Hill, 2014), sec. 11-10, eqs. 11-95 to 11-103 and Example 11-16

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.