FireCADCalc

Four-Bar Linkage: Grashof Check and Transmission Angle

Grashof classification of a four-bar linkage from its link lengths, the linkage type, and the minimum and maximum transmission angles.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Crank–rocker 50/150/120/140 mmDouble crank: shortest is ground

Results

Transmission angle extremes occur with the crank in line with the ground link; keep the minimum above about 40° for smooth force transmission. Angles valid when the crank fully rotates.

Grashof margin (≤ 0 means Grashof)-40.000mm
Type (1 crank–rocker, 2 double crank, 3 double rocker, 4 non-Grashof)2.0000
Minimum transmission angle24.620°
Maximum transmission angle81.285°

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Crank–rocker 50/150/120/140 mm. The inputs, in the units selected above:

InputValue
Crank (input) length50.000 mm
Coupler length150.00 mm
Rocker (output) length120.00 mm
Fixed (ground) link length140.00 mm

Applying the formula below gives:

ResultValue
Grashof margin (≤ 0 means Grashof)-60.000 mm
Type (1 crank–rocker, 2 double crank, 3 double rocker, 4 non-Grashof)1.0000
Minimum transmission angle36.870 °
Maximum transmission angle88.727 °

Open this example in the calculator and change any input.

Formula

\(s + l \le p + q\ \text{(Grashof)}, \quad \cos\mu = \frac{b^2 + c^2 - (d \mp a)^2}{2bc}\)

Variables

Symbol Meaning SI unit
\(a\) Crank (input) length m
\(b\) Coupler length m
\(c\) Rocker (output) length m
\(d\) Fixed (ground) link length m
\(s + l - p - q\) Grashof margin (≤ 0 means Grashof) m
\(\text{type}\) Type (1 crank–rocker, 2 double crank, 3 double rocker, 4 non-Grashof) -
\(\mu_{min}\) Minimum transmission angle rad
\(\mu_{max}\) Maximum transmission angle rad

Method and standards

Grashof's law and transmission angle extremes.

Where it is used

  • Linkage design for packaging and machine tools.
  • Checking existing mechanisms.

Common mistakes

  • Mislabelling the ground link.
  • Ignoring the transmission angle.

Assumptions and limits

  • Planar pin-jointed four-bar.
  • Type codes: 1 crank–rocker, 2 double crank, 3 double rocker, 4 non-Grashof. A change-point linkage (s + l = p + q) is flagged.
  • The transmission angle extremes are shown only when link a turns fully (Grashof, with a or the ground link shortest).

References

  • Rattan
  • Theory of Machines
  • 4th ed. (McGraw-Hill, 2014); Bhandari
  • Design of Machine Elements
  • 4th ed. (McGraw-Hill, 2017) (Grashof's law; transmission angle)

Questions and answers

What is Grashof's law?

If the shortest plus longest link is no more than the sum of the other two, at least one link can rotate fully.

Why care about transmission angle?

Near 0° or 180° the coupler pushes almost along the output link and little torque is transmitted; the mechanism can jam.

What do the defaults represent?

A crank–rocker with 50, 150, 120 and 140 mm links.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.