FireCADCalc

Eccentrically Loaded Bolt Group (Circular Pattern) in Shear

Largest bolt force in a circular bolt group carrying an eccentric shear load: direct shear plus the torsional shear from the moment, and the bolt stress.

Inputs

Examples: 20 kN at 300 mm, six bolts on 100 mm radius, M168 kN at 150 mm, four bolts on 60 mm50 kN at 500 mm, eight on 200 mm

Results

Elastic method: bolts equally stiff, plates rigid. The load is taken perpendicular to the line through the centre, with one bolt on the load line.

Direct (primary) shear per bolt F/n2.0000kN
Torsional (secondary) shear per bolt F e r/Σr²5.0000kN
Largest resultant bolt force7.0000kN
Shear stress in that bolt61.894MPa

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 20 kN at 300 mm, six bolts on 100 mm radius, M16. The inputs, in the units selected above:

InputValue
Shear load on the group20.000 kN
Eccentricity of the load from the group centre300.00 mm
Number of bolts on the circle6.0000 -
Radius of the bolt circle100.00 mm
Bolt diameter in shear16.000 mm

Applying the formula below gives:

ResultValue
Direct (primary) shear per bolt F/n3.3333 kN
Torsional (secondary) shear per bolt F e r/Σr²10.0000 kN
Largest resultant bolt force13.333 kN
Shear stress in that bolt66.315 MPa

Open this example in the calculator and change any input.

Formula

\(F' = \frac{F}{n}, \quad F'' = \frac{F e\, r}{\sum r_i^2} = \frac{F e}{n r}, \quad F_{max} = \left|\vec F' + \vec F''\right|_{max}\)

Variables

Symbol Meaning SI unit
\(F\) Shear load on the group N
\(e\) Eccentricity of the load from the group centre m
\(n\) Number of bolts on the circle -
\(r\) Radius of the bolt circle m
\(d\) Bolt diameter in shear m
\(F'\) Direct (primary) shear per bolt F/n N
\(F''\) Torsional (secondary) shear per bolt F e r/Σr² N
\(F_{max}\) Largest resultant bolt force N
\(\tau\) Shear stress in that bolt Pa

Method and standards

Elastic analysis of a bolt group.

Where it is used

  • Brackets and crane connections.
  • Machine design examinations.

Common mistakes

  • Adding magnitudes without direction.
  • Using bolt thread area for fitted bolts.

Assumptions and limits

  • Equal bolts, rigid plates.
  • Shear stress on the nominal (shank) area: if the threads lie in the shear plane use the root area, which gives a higher stress. The stress is not compared with an allowable.

References

  • Shigley's Mechanical Engineering Design (Budynas and Nisbett)
  • ch. 8 (shear joints with eccentric loading, elastic method)

Questions and answers

20 kN at 300 mm on six bolts on a 100 mm radius?

Direct 3333 N, torsional 10000 N per bolt; worst bolt about 13333 N where they add.

Why does eccentricity dominate?

The moment F e grows with the lever arm while direct shear is fixed.

Rectangular patterns?

Use Σr² of the actual bolt positions; this calculator covers circular patterns.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.