Worked example
Example: Illustrative reference window. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Window width (overall) | 1.2300 m |
| Window height (overall) | 1.4800 m |
| Frame face width (uniform) | 110.00 mm |
| Glazing centre U-value | 1.1000 W/(m²·K) |
| Frame U-value | 1.4000 W/(m²·K) |
| Edge linear thermal transmittance | 0.060000 W/(m·K) |
| Inside–outside temperature difference | 20.000 K |
Applying the formula below gives:
| Result | Value |
|---|---|
| Glazed area | 1.2726 m² |
| Frame area | 0.54780 m² |
| Glass edge perimeter | 4.5400 m |
| Window U-value | 1.3399 W/(m²·K) |
| Heat loss through the window | 48.784 W |
Open this example in the calculator and change any input.
Formula
\(U_w = \frac{A_gU_g + A_fU_f + l_g\Psi_g}{A_g + A_f}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(W\) | Window width (overall) | m |
| \(H\) | Window height (overall) | m |
| \(b_f\) | Frame face width (uniform) | m |
| \(U_g\) | Glazing centre U-value | W/(m²·K) |
| \(U_f\) | Frame U-value | W/(m²·K) |
| \(\Psi_g\) | Edge linear thermal transmittance | W/(m·K) |
| \(\Delta T\) | Inside–outside temperature difference | K |
| \(A_g\) | Glazed area | m² |
| \(A_f\) | Frame area | m² |
| \(l_g\) | Glass edge perimeter | m |
| \(U_w\) | Window U-value | W/(m²·K) |
| \(\dot Q\) | Heat loss through the window | W |
Method and standards
Window U-value.
Where it is used
- Envelope compliance and heat loss.
- Comparing frame and spacer options.
Common mistakes
- Using the glazing U-value for the whole window.
- Forgetting the edge term.
Assumptions and limits
- Uniform frame width; one glazed pane unit.
References
- Area-weighted window thermal transmittance
- ISO 10077-1
- Thermal performance of windows
- doors and shutters: Calculation of thermal transmittance
- Part 1 (method equation)
Questions and answers
Why is the window U-value worse than the glass U-value?
Frames usually conduct more than modern glazing, and the spacer adds an edge heat flow.
What is Ψ_g?
The extra heat flow per metre of glass edge caused by the spacer and frame interaction.
What do the defaults represent?
An illustrative 1.23 × 1.48 m window, 110 mm frame, U_g = 1.1, U_f = 1.4 W/m²·K, Ψ = 0.06 W/m·K at 20 K.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.