A long horizontal overhang casts a shadow line whose depth below its edge is P·tan Ω, where the profile angle Ω is the sun's altitude projected onto a vertical plane normal to the wall: tan Ω = tan β/cos γ. The glass from the head down to that line is shaded, less the gap between overhang and head. South-facing (north in the southern hemisphere) overhangs shade high summer sun and admit low winter sun; on east and west walls the low sun gets under them, so vertical fins or external blinds work better there. End effects of a finite overhang are ignored.

Profile (vertical shadow) angle25.338°
Shadow depth below the overhang0.28410m
Shaded fraction of the window0%
Sunlit glass area2.7000m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 0.6 m overhang, sun at 60 degrees. The inputs, in the units selected above:

InputValue
Overhang projection0.60000 m
Gap from overhang to window head0.30000 m
Window height1.5000 m
Window width1.8000 m
Solar altitude60.000 °
Wall-solar azimuth (sun relative to wall normal)20.000 °

Applying the formula below gives:

ResultValue
Profile (vertical shadow) angle61.519 °
Shadow depth below the overhang1.1059 m
Shaded fraction of the window53.728 %
Sunlit glass area1.2493 m²

Open this example in the calculator and change any input.

Formula

\(\tan\Omega = \frac{\tan\beta}{\cos\gamma}, \quad y = P\tan\Omega, \quad f_s = \frac{\min(H, \max(0, y - G))}{H}\)

Variables

Symbol Meaning SI unit
\(P\) Overhang projection m
\(G\) Gap from overhang to window head m
\(H\) Window height m
\(W\) Window width m
\(\beta\) Solar altitude rad
\(\gamma\) Wall-solar azimuth (sun relative to wall normal) rad
\(\Omega\) Profile (vertical shadow) angle rad
\(y\) Shadow depth below the overhang m
\(f_s\) Shaded fraction of the window -
\(A_{sun}\) Sunlit glass area m²

Method and standards

Overhang shading.

Where it is used

  • Passive solar design and cooling load reduction.
  • Checking shading at design hours.

Common mistakes

  • Using the solar altitude instead of the profile angle off-normal.
  • Ignoring the gap above the window.

Assumptions and limits

  • Infinitely long overhang; direct beam only.

References

  • Shading by horizontal projections

Questions and answers

What overhang depth shades a window fully at noon in summer?

Projection = (gap + window height)/tan Ω at the design sun position.

Why does an overhang not work on a west wall?

The afternoon sun is low, so the profile angle is small and the shadow barely reaches the glass.

What do the defaults represent?

An illustrative 0.6 m overhang, 0.3 m above a 1.5 × 1.8 m window, sun at 60° altitude and 20° off the wall normal.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

McQuiston, Parker, Spitler and Taherian, Heating, Ventilating and Air Conditioning, and ASHRAE, Principles of Heating, Ventilating and Air Conditioning, 8th ed. (ASHRAE, 2017)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.