Interstitial Condensation Risk in a Wall (Glaser Method)

Temperatures, vapour pressures and saturation margins at the surfaces and interfaces of a three-layer wall by the Glaser method, showing where condensation can form.

Food, dairy and textile

Inputs

Examples: Illustrative plasterboard, wool, brick, no barrierWith vapour barrier on the warm sideExternal insulation on concrete

Accepted: -10 to 40 °C
Accepted: 5 to 100 %
Accepted: -40 to 40 °C
Accepted: 5 to 100 %
Accepted: 0 to 1 m²·K/W
Accepted: 0 to 1 m²·K/W
Accepted: 0 to 1,000 mm
Accepted: 0.01 to 5 W/(m·K)
Accepted: 1 to 1,000,000
Accepted: 0 to 1,000 mm
Accepted: 0.01 to 5 W/(m·K)
Accepted: 1 to 1,000,000
Accepted: 0 to 1,000 mm
Accepted: 0.01 to 5 W/(m·K)
Accepted: 1 to 1,000,000

Results

Steady-state Glaser method: temperatures from thermal resistances, vapour pressure falling linearly with vapour diffusion thickness s_d = μd (surface vapour resistances neglected). A negative margin means vapour pressure would exceed saturation there: condensation is predicted; add a vapour control layer on the warm side or ventilate the cold side.

Thermal transmittance0.34972W/(m²·K)
Inside surface temperature18.863°C
Temperature at the layer 1–2 interface18.343°C
Temperature at the layer 2–3 interface-3.5148°C
Outside surface temperature-4.6503°C
Smallest saturation margin (negative = condensation)52.350Pa
Plane of smallest margin (1 inside surface … 4 outside surface)4.0000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative plasterboard, wool, brick, no barrier. The inputs, in the units selected above:

InputValue
Indoor temperature20.000 °C
Indoor relative humidity60.000 %
Outdoor temperature-5.0000 °C
Outdoor relative humidity90.000 %
Inside surface resistance0.13000 m²·K/W
Outside surface resistance0.040000 m²·K/W
Layer 1 (inside) thickness12.500 mm
Layer 1 conductivity0.21000 W/(m·K)
Layer 1 vapour resistance factor10.000 -
Layer 2 thickness100.00 mm
Layer 2 conductivity0.040000 W/(m·K)
Layer 2 vapour resistance factor1.0000 -
Layer 3 (outside) thickness100.00 mm
Layer 3 conductivity0.77000 W/(m·K)
Layer 3 vapour resistance factor10.000 -

Applying the formula below gives:

ResultValue
Thermal transmittance0.34972 W/(m²·K)
Inside surface temperature18.863 °C
Temperature at the layer 1–2 interface18.343 °C
Temperature at the layer 2–3 interface-3.5148 °C
Outside surface temperature-4.6503 °C
Smallest saturation margin (negative = condensation)-756.34 Pa
Plane of smallest margin (1 inside surface … 4 outside surface)3.0000

Open this example in the calculator and change any input.

Formula

\(T_{j+1} = T_j - q\frac{d_j}{\lambda_j}, \quad p(s_d) = p_i - (p_i - p_o)\frac{s_d}{s_{d,tot}}, \quad s_d = \mu d\)

Variables

Symbol Meaning SI unit
\(T_i\) Indoor temperature K
\(\varphi_i\) Indoor relative humidity -
\(T_o\) Outdoor temperature K
\(\varphi_o\) Outdoor relative humidity -
\(R_{si}\) Inside surface resistance m²·K/W
\(R_{so}\) Outside surface resistance m²·K/W
\(d_1\) Layer 1 (inside) thickness m
\(\lambda_1\) Layer 1 conductivity W/(m·K)
\(\mu_1\) Layer 1 vapour resistance factor -
\(d_2\) Layer 2 thickness m
\(\lambda_2\) Layer 2 conductivity W/(m·K)
\(\mu_2\) Layer 2 vapour resistance factor -
\(d_3\) Layer 3 (outside) thickness m
\(\lambda_3\) Layer 3 conductivity W/(m·K)
\(\mu_3\) Layer 3 vapour resistance factor -
\(U\) Thermal transmittance W/(m²·K)
\(T_{si}\) Inside surface temperature K
\(T_{12}\) Temperature at the layer 1–2 interface K
\(T_{23}\) Temperature at the layer 2–3 interface K
\(T_{so}\) Outside surface temperature K
\(\min(p_s - p)\) Smallest saturation margin (negative = condensation) Pa
\(k\) Plane of smallest margin (1 inside surface … 4 outside surface) -

Method and standards

Glaser diagram.

Where it is used

  • Wall and roof build-up design.
  • Retrofit internal insulation checks.

Common mistakes

  • Placing vapour-tight layers on the cold side.
  • Treating the steady method as a moisture-content prediction.

Assumptions and limits

  • Steady state; one-dimensional; no liquid transport.

References

  • Glaser steady-state vapour diffusion method

Questions and answers

Why does insulation inside a masonry wall risk condensation?

The masonry outside the insulation is cold, but vapour passes easily through the insulation, so it reaches the cold layer above its dew point.

Where should the vapour barrier go?

On the warm side of the insulation, so the vapour pressure drops before the temperature does.

What do the defaults represent?

An illustrative 12.5 mm plasterboard, 100 mm mineral wool and 100 mm brick wall at 20 °C, 60 % inside and −5 °C, 90 % outside, with no vapour barrier.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Hagentoft, Introduction to Building Physics (Studentlitteratur, 2001)

Related calculators