Worked example
Example: 210 MW: 640 t/h at 150 bar(a) / 540 °C, feed 245 °C, eco out 300 °C; reheat 560 t/h at 40 bar(a) 340 to 540 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Main steam flow | 640,000 kg/h |
| Main steam (drum) pressure (absolute) | 150.00 bar |
| Main steam temperature | 540.00 °C |
| Feedwater temperature at economiser inlet | 245.00 °C |
| Water temperature leaving the economiser | 300.00 °C |
| Reheat steam flow (0 = no reheat) | 560,000 kg/h |
| Reheat pressure (absolute) | 40.000 bar |
| Cold reheat temperature | 340.00 °C |
| Hot reheat temperature | 540.00 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Total heat to water and steam | 492.67 MW |
| Economiser | 48.992 MW |
| Evaporator (furnace walls) | 226.28 MW |
| Superheater | 144.42 MW |
| Reheater | 72.986 MW |
Open this example in the calculator and change any input.
Formula
\(\dot Q_{eco} = \dot m (h_{eco} - h_{fw}) \qquad \dot Q_{ev} = \dot m (h_g - h_{eco}) \qquad \dot Q_{sh} = \dot m (h_{ms} - h_g) \qquad \dot Q_{rh} = \dot m_{rh} (h_{hrh} - h_{crh})\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_{ms}\) | main steam flow | kg/s |
| \(p\) | main steam pressure | Pa |
| \(T_{ms}\) | main steam temperature | K |
| \(T_{fw}\) | feedwater temperature | K |
| \(T_{eco}\) | economiser outlet temperature | K |
| \(\dot m_{rh}\) | reheat flow | kg/s |
| \(p_{rh}\) | reheat pressure | Pa |
| \(T_{crh}\) | cold reheat temperature | K |
| \(T_{hrh}\) | hot reheat temperature | K |
| \(\dot Q\) | total duty | W |
| \(\dot Q_{eco}\) | economiser | W |
| \(\dot Q_{ev}\) | evaporator | W |
| \(\dot Q_{sh}\) | superheater | W |
| \(\dot Q_{rh}\) | reheater | W |
| \(\dot m\) | main steam flow | kg/s |
| \(h\) | enthalpies (IF97) | J/kg |
Method and standards
Enthalpy differences from FireCAD's IAPWS-IF97 at one pressure for economiser, drum and superheater.
Where it is used
- Boiler concept design and surface allocation.
- Explaining how pressure changes the absorption pattern.
- Checking heat balance diagrams.
Common mistakes
- Ignoring spray flow, which shifts duty from superheater to evaporator.
- Using turbine inlet instead of boiler outlet conditions.
- Forgetting reheat flow differs from main steam flow.
Assumptions and limits
- One pressure for economiser, drum and superheater; no blowdown or spray. The real drum runs above the main steam pressure, which moves a little duty from the evaporator to the superheater.
- The hot reheat must be hotter than the cold reheat.
References
- IAPWS R7-97 IF97
Questions and answers
How does a 210 MW boiler's heat split?
640 t/h at 150 bar(a) and 540 °C from 245 °C feedwater (economiser to 300 °C) with 560 t/h reheated from 340 to 540 °C at 40 bar(a) takes 493 MW: economiser 49, furnace walls 226, superheater 144, reheater 73 MW.
Why does the split matter?
It decides how much surface goes where; at higher pressure less heat goes to evaporation and more to superheat and reheat.
What is left out?
Pressure drops, blowdown, attemperator spray and the drum's own losses.