Boiler Heat Duty Split (Economiser, Evaporator, SH, RH)

How a boiler's heat duty splits between economiser, evaporator, superheater and reheater, from the steam, feedwater and reheat conditions (IAPWS-IF97).

Thermal power plantSugar mill and cogenerationPulp and paperIAPWS-IF97 (water and steam)BoilerEconomiser and air preheater

Inputs

Examples: 210 MW: 640 t/h at 150 bar(a) / 540 °C, feed 245 °C, eco out 300 °C; reheat 560 t/h at 40 bar(a) 340 to 540 °C100 t/h at 105 bar(a) / 540 °C, feed 215 °C, eco 260 °C; no reheat500 MW: 1600 t/h at 175 bar(a) / 540 °C, feed 255 °C, eco 310 °C; 1400 t/h at 42 bar(a) 345 to 568 °C

Main steam

Reheat

Results

One pressure is used for economiser, drum and superheater; pressure drops, blowdown and attemperator spray are not included.

Total heat to water and steam492.67MW
Economiser48.992MW
Evaporator (furnace walls)226.28MW
Superheater144.42MW
Reheater72.986MW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 210 MW: 640 t/h at 150 bar(a) / 540 °C, feed 245 °C, eco out 300 °C; reheat 560 t/h at 40 bar(a) 340 to 540 °C. The inputs, in the units selected above:

InputValue
Main steam flow640,000 kg/h
Main steam (drum) pressure (absolute)150.00 bar
Main steam temperature540.00 °C
Feedwater temperature at economiser inlet245.00 °C
Water temperature leaving the economiser300.00 °C
Reheat steam flow (0 = no reheat)560,000 kg/h
Reheat pressure (absolute)40.000 bar
Cold reheat temperature340.00 °C
Hot reheat temperature540.00 °C

Applying the formula below gives:

ResultValue
Total heat to water and steam492.67 MW
Economiser48.992 MW
Evaporator (furnace walls)226.28 MW
Superheater144.42 MW
Reheater72.986 MW

Open this example in the calculator and change any input.

Formula

\(\dot Q_{eco} = \dot m (h_{eco} - h_{fw}) \qquad \dot Q_{ev} = \dot m (h_g - h_{eco}) \qquad \dot Q_{sh} = \dot m (h_{ms} - h_g) \qquad \dot Q_{rh} = \dot m_{rh} (h_{hrh} - h_{crh})\)

Variables

Symbol Meaning SI unit
\(\dot m_{ms}\) main steam flow kg/s
\(p\) main steam pressure Pa
\(T_{ms}\) main steam temperature K
\(T_{fw}\) feedwater temperature K
\(T_{eco}\) economiser outlet temperature K
\(\dot m_{rh}\) reheat flow kg/s
\(p_{rh}\) reheat pressure Pa
\(T_{crh}\) cold reheat temperature K
\(T_{hrh}\) hot reheat temperature K
\(\dot Q\) total duty W
\(\dot Q_{eco}\) economiser W
\(\dot Q_{ev}\) evaporator W
\(\dot Q_{sh}\) superheater W
\(\dot Q_{rh}\) reheater W
\(\dot m\) main steam flow kg/s
\(h\) enthalpies (IF97) J/kg

Method and standards

Enthalpy differences from FireCAD's IAPWS-IF97 at one pressure for economiser, drum and superheater.

Where it is used

  • Boiler concept design and surface allocation.
  • Explaining how pressure changes the absorption pattern.
  • Checking heat balance diagrams.

Common mistakes

  • Ignoring spray flow, which shifts duty from superheater to evaporator.
  • Using turbine inlet instead of boiler outlet conditions.
  • Forgetting reheat flow differs from main steam flow.

Assumptions and limits

  • One pressure for economiser, drum and superheater; no blowdown or spray. The real drum runs above the main steam pressure, which moves a little duty from the evaporator to the superheater.
  • The hot reheat must be hotter than the cold reheat.

References

  • IAPWS R7-97 IF97

Questions and answers

How does a 210 MW boiler's heat split?

640 t/h at 150 bar(a) and 540 °C from 245 °C feedwater (economiser to 300 °C) with 560 t/h reheated from 340 to 540 °C at 40 bar(a) takes 493 MW: economiser 49, furnace walls 226, superheater 144, reheater 73 MW.

Why does the split matter?

It decides how much surface goes where; at higher pressure less heat goes to evaporation and more to superheat and reheat.

What is left out?

Pressure drops, blowdown, attemperator spray and the drum's own losses.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.