FireCADCalc

Fuel Saving from Higher Feedwater Temperature

Fuel saved when the feedwater enters the boiler hotter (economiser, condensate return, feed heater), from the steam conditions and IAPWS-IF97 enthalpies.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)BoilerEconomiser and air preheaterDeaerator and feedwater systemBoiler attendant and boiler operator examinations

Inputs

Examples: 10 t/h at 10.5 bar(a) saturated, feed 80 to 105 °C50 t/h at 66 bar(a) / 485 °C, feed 105 to 150 °C5 t/h at 8 bar(a) saturated, feed 30 to 90 °C (condensate return)

Results

Fuel saved, share6.5097%
Fuel saved604.18kg/h
Fuel now9,281.2kg/h
Fuel after8,677.0kg/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 t/h at 10.5 bar(a) saturated, feed 80 to 105 °C. The inputs, in the units selected above:

InputValue
Steam flow10,000 kg/h
Steam pressure (absolute)10.500 bar
Steam conditionDry saturated
Steam temperature (superheated only)250.00 °C
Feedwater temperature now80.000 °C
Feedwater temperature after105.00 °C
Boiler efficiency (on GCV)80.000 %
Gross calorific value of the fuel, as fired18,600 kJ/kg

Applying the formula below gives:

ResultValue
Fuel saved, share4.3039 %
Fuel saved70.668 kg/h
Fuel now1,641.9 kg/h
Fuel after1,571.3 kg/h

Open this example in the calculator and change any input.

Formula

\(\dot m_{f,1} = \frac{\dot m_s\,(h_s - h_{fw,1})}{\eta_1\,GCV} \qquad \dot m_{f,2} = \frac{\dot m_s\,(h_s - h_{fw,2})}{\eta_1\,GCV}\)

\(\Delta\dot m_f = \dot m_{f,1} - \dot m_{f,2} \qquad s = 1 - \frac{\dot m_{f,2}}{\dot m_{f,1}}\)

Variables

Symbol Meaning SI unit
\(\dot m_s\) steam flow kg/s
\(p\) steam pressure, absolute Pa
\(\text{state}\) saturated or superheated steam –
\(T_s\) steam temperature (superheated) K
\(T_{fw,1}\) feedwater temperature now K
\(T_{fw,2}\) feedwater temperature after K
\(\eta_1\) boiler efficiency on GCV –
\(GCV\) gross calorific value J/kg
\(s\) fuel saved, share –
\(\Delta\dot m_f\) fuel saved kg/s
\(\dot m_{f,1}\) fuel now kg/s
\(\dot m_{f,2}\) fuel after kg/s
\(h_s\) steam enthalpy J/kg
\(h_{fw,1}\), \(h_{fw,2}\) feedwater enthalpies now and after J/kg

Method and standards

Fuel for the same steam output before and after, from the heat added per kg of steam with enthalpies from FireCAD's IAPWS-IF97 and the same boiler efficiency.

Where it is used

  • Condensate recovery and feed tank heating projects in process plants.
  • Valuing an economiser or a blowdown heat exchanger.
  • Explaining the cost of a cold feed tank after condensate is lost.

Common mistakes

  • Heating feedwater with live steam and counting it as a fuel saving.
  • Raising feed tank temperature above what the feed pump's NPSH allows: hot water can cavitate the pump.
  • Assuming the economiser recovers the same heat with hotter water.

Assumptions and limits

  • Same steam flow, conditions and boiler efficiency before and after.
  • Feedwater liquid at boiler pressure.
  • With an economiser, hotter feedwater lowers the economiser's recovery, so the saving here is an upper bound when the extra heat comes from the economiser itself.
  • A colder feedwater after gives a negative saving, with a note.

References

  • IAPWS R7-97(2012) IF97
  • first law heat balance

Questions and answers

How much fuel does hotter feedwater save?

A 10 t/h boiler at 10.5 bar(a) saturated, with feedwater raised from 80 to 105 °C, needs 4.3 % less fuel for the same steam: 70.7 kg/h of coal at 18.6 MJ/kg and 80 % efficiency. That is close to the rule of thumb of 1 % per 6 K.

Where can the feedwater heat come from?

Returned condensate, flash steam, blowdown heat recovery, an economiser, or exhaust steam in a deaerator. Heat from the flue gas or waste streams saves fuel; heat from live steam does not.

Does efficiency change too?

This calculator keeps the efficiency the same. With an economiser, hotter feedwater also raises the economiser outlet and may lower its heat recovery slightly; check with the economiser balance.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.