FireCADCalc

RO Limiting Salt: Maximum Recovery Before Scaling

Maximum reverse osmosis recovery before a sparingly soluble salt such as calcium, barium or strontium sulfate reaches saturation at the membrane surface.

Inputs

Examples: Strontium sulfate 2 mg/L Sr, 400 mg/L SO4

Accepted: 1E-6 to 1,000 mg/L
Accepted: 1 to 300 kg/kmol
Accepted: 1E-6 to 5,000 mg/L
Accepted: 1 to 300 kg/kmol
Accepted: -20 to 0
Accepted: 1 to 2

Results

100 % rejection and activities equal to concentrations, in common practice; activity coefficients below 1 allow somewhat higher recovery. Antiscalants let plants exceed the saturation limit by a margin set by the supplier.

Cation in the feed2.2826e-05mol/L
Anion in the feed0.004164mol/L
Concentrate fraction at saturation65.789%
Maximum recovery34.211%
Concentration factor at the limit1.5200

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Strontium sulfate 2 mg/L Sr, 400 mg/L SO4. The inputs, in the units selected above:

InputValue
Cation in the feed (Ca, Ba or Sr)2.0000 mg/L
Cation molar mass (Ca 40.08, Ba 137.33, Sr 87.62)87.620 kg/kmol
Anion in the feed (sulfate)400.00 mg/L
Anion molar mass (SO4 96.06)96.060 kg/kmol
Log of the solubility product (CaSO4 −4.6, BaSO4 −9.97, SrSO4 −6.5)-6.5000 -
Concentration polarisation factor1.2000 -

Applying the formula below gives:

ResultValue
Cation in the feed2.2826e-05 mol/L
Anion in the feed0.004164 mol/L
Concentrate fraction at saturation65.789 %
Maximum recovery34.211 %
Concentration factor at the limit1.5200

Open this example in the calculator and change any input.

Formula

\(K_{sp} = [M^{2+}]_M[A^{2-}]_M = \frac{\beta^2[M^{2+}]_F[A^{2-}]_F}{y^2}\)

\(y = 1 - r = \beta\sqrt{\frac{[M^{2+}]_F[A^{2-}]_F}{K_{sp}}}\)

Variables

Symbol Meaning SI unit
\(C_{cat}\) Cation in the feed (Ca, Ba or Sr) kg/m³
\(M_{cat}\) Cation molar mass (Ca 40.08, Ba 137.33, Sr 87.62) kg/kmol
\(C_{an}\) Anion in the feed (sulfate) kg/m³
\(M_{an}\) Anion molar mass (SO4 96.06) kg/kmol
\(\log K_{sp}\) Log of the solubility product (CaSO4 −4.6, BaSO4 −9.97, SrSO4 −6.5) -
\(\beta\) Concentration polarisation factor -
\([M^{2+}]_F\) Cation in the feed mol/m³
\([A^{2-}]_F\) Anion in the feed mol/m³
\(y = 1 - r\) Concentrate fraction at saturation -
\(r_{max}\) Maximum recovery -
\(CF\) Concentration factor at the limit -

Method and standards

Solubility product at the membrane surface with full rejection.

Where it is used

  • Setting RO recovery and antiscalant needs.
  • Comparing waters for RO.

Common mistakes

  • Ignoring polarisation.
  • Using mg/L instead of mol/L in K_sp.

Assumptions and limits

  • 1:1 divalent salts, full rejection, activity = concentration.

Questions and answers

Which salt limits recovery?

Check each sparingly soluble salt; the one giving the lowest recovery is the limiting salt. Barium sulfate often limits even at µg/L barium.

Why include polarisation?

The concentration at the membrane surface is β times the bulk value, so scaling starts there first.

What do the defaults represent?

An illustrative case: Strontium sulfate 2 mg/L Sr, 400 mg/L SO4. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 17-6, eq. 17-47 and Example 17-4

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.