FireCADCalc

Coagulant Feed Rate, Alkalinity Consumed and Precipitate (Alum, FeCl3)

Stock strength, chemical feed rate, alkalinity consumed, hydroxide precipitate and caustic to restore alkalinity for an alum or ferric chloride coagulant dose.

Inputs

Examples: Ferric chloride 40 % FeCl3, SG 1.42, 25 mg/L, 20,000 m3/dAlum 8.3 %, SG 1.33, 60 mg/L monsoon dose, 5,000 m3/d

Accepted: 0.1 to 100 %
Accepted: 1 to 2
Accepted: 0 to 500 mg/L
Accepted: 8.64 to 8,640,000 m³/d

Results

Stoichiometric: each Al³⁺ or Fe³⁺ consumes 3 equivalents of alkalinity and precipitates as the hydroxide. Real sludge is more (bound water, organics, turbidity solids); use the sludge calculator for the total.

Metal ion in the stock3.5020mol/L
Stock concentration as the dosed product568.00g/L
Stock feed rate0.61131L/min
Alkalinity consumed (as CaCO3)23.140mg/L
Hydroxide precipitate16.472mg/L
Precipitate per day329.44kg/d
Caustic to restore the alkalinity18.495mg/L
Caustic per day369.90kg/d

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Ferric chloride 40 % FeCl3, SG 1.42, 25 mg/L, 20,000 m3/d. The inputs, in the units selected above:

InputValue
CoagulantFerric chloride, FeCl3 (stock strength as % FeCl3)
Stock strength (mass fraction, as stated)40.000 %
Stock specific gravity1.4200 -
Dose (as Al2(SO4)3·14H2O or FeCl3)25.000 mg/L
Plant flow20,000 m³/d

Applying the formula below gives:

ResultValue
Metal ion in the stock3.5020 mol/L
Stock concentration as the dosed product568.00 g/L
Stock feed rate0.61131 L/min
Alkalinity consumed (as CaCO3)23.140 mg/L
Hydroxide precipitate16.472 mg/L
Precipitate per day329.44 kg/d
Caustic to restore the alkalinity18.495 mg/L
Caustic per day369.90 kg/d

Open this example in the calculator and change any input.

Formula

\(\text{Al}_2(\text{SO}_4)_3\cdot14\text{H}_2\text{O} + 6\text{HCO}_3^- \rightarrow 2\text{Al(OH)}_3 + 3\text{SO}_4^{2-} + 6\text{CO}_2 + 14\text{H}_2\text{O}\)

\(\text{FeCl}_3 + 3\text{HCO}_3^- \rightarrow \text{Fe(OH)}_3 + 3\text{Cl}^- + 3\text{CO}_2, \quad Q_{feed} = \frac{DQ}{C_{stock}}\)

Variables

Symbol Meaning SI unit
\(\text{coagulant}\) Coagulant -
\(w\) Stock strength (mass fraction, as stated) -
\(SG\) Stock specific gravity -
\(D\) Dose (as Al2(SO4)3·14H2O or FeCl3) kg/m³
\(Q\) Plant flow m³/s
\([M^{3+}]\) Metal ion in the stock mol/m³
\(C_{stock}\) Stock concentration as the dosed product kg/m³
\(Q_{feed}\) Stock feed rate m³/s
\(\Delta Alk\) Alkalinity consumed (as CaCO3) kg/m³
\(M(OH)_3\) Hydroxide precipitate kg/m³
\(\dot m_{ppt}\) Precipitate per day kg/s
\(NaOH\) Caustic to restore the alkalinity kg/m³
\(\dot m_{NaOH}\) Caustic per day kg/s

Method and standards

Stoichiometry of metal-salt coagulation with IUPAC atomic masses.

Where it is used

  • Setting coagulant pump rates.
  • Checking alkalinity and pH correction chemical for soft waters.

Common mistakes

  • Mixing dose 'as product' with dose 'as Al' or 'as Al₂O₃'.
  • Forgetting the stock density when converting % to g/L.

Assumptions and limits

  • Stoichiometric alkalinity and precipitate; no allowance for hydrolysis species or NOM.

Questions and answers

Why does alum lower the pH?

Each mole of alum consumes six equivalents of bicarbonate alkalinity and releases CO₂; in soft, low-alkalinity water the pH can fall below the coagulation optimum, so caustic, lime or soda ash is added.

Why is alum strength given as % Al₂O₃?

It is the trade convention for liquid alum; 8.3–8.5 % Al₂O₃ liquid alum is about 49 % as Al₂(SO₄)₃·14H₂O.

What do the defaults represent?

An illustrative case: Ferric chloride 40 % FeCl3, SG 1.42, 25 mg/L, 20,000 m3/d. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 9-4, eqs. 9-11 and 9-12, Example 9-2

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.