Ferrous Iron Oxidation by Aeration: Rate, CMFR and PFR Volume

Pseudo-first-order rate of ferrous iron oxygenation from pH and oxygen, and the detention time and volume of completely mixed or plug-flow reactors.

Inputs

Examples: pH 6.5 groundwater, 3 to 0.1 mg/L, 2,000 m3/dAfter lime to pH 7.5, 8 to 0.2 mg/L, 5,000 m3/d

Accepted: 0.001 to 100 mg/L
Accepted: 1E-4 to 100 mg/L
Accepted: 5.5 to 9
Accepted: 0.01 to 1
Accepted: 1E+10 to 1E+16
Accepted: 0.864 to 8,640,000 m³/d

Results

Rate law −d[Fe²⁺]/dt = k[OH⁻]²P_O₂[Fe²⁺] (Stumm and Lee) with [OH⁻] from pK_w = 14. The rate rises 100-fold per pH unit; iron bound to natural organic matter oxidises far more slowly, so confirm by bench tests.

Pseudo-first-order rate constant0.0168001/min
Completely mixed reactor detention1,726.2min
Completely mixed reactor volume2,397.5m³
Plug-flow reactor detention202.45min
Plug-flow reactor volume281.18m³
Half-life of Fe²⁺41.259min

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: pH 6.5 groundwater, 3 to 0.1 mg/L, 2,000 m3/d. The inputs, in the units selected above:

InputValue
Initial ferrous iron3.0000 mg/L
Target ferrous iron0.10000 mg/L
pH6.5000 -
Oxygen partial pressure (air 0.21 atm)0.21000 -
Rate constant (Stumm and Lee: 8 × 10¹³ L²/(mol²·atm·min) at 20 °C)8.0000e+13 -
Flow2,000.0 m³/d

Applying the formula below gives:

ResultValue
Pseudo-first-order rate constant0.016800 1/min
Completely mixed reactor detention1,726.2 min
Completely mixed reactor volume2,397.5 m³
Plug-flow reactor detention202.45 min
Plug-flow reactor volume281.18 m³
Half-life of Fe²⁺41.259 min

Open this example in the calculator and change any input.

Formula

\(-\frac{d[\text{Fe}^{2+}]}{dt} = k[\text{OH}^-]^2P_{O_2}[\text{Fe}^{2+}] = k_r[\text{Fe}^{2+}]\)

\(\tau_{CMFR} = \frac{C_0 - C_e}{k_rC_e}, \quad \tau_{PFR} = \frac{1}{k_r}\ln\frac{C_0}{C_e}\)

Variables

Symbol Meaning SI unit
\(C_0\) Initial ferrous iron kg/m³
\(C_e\) Target ferrous iron kg/m³
\(pH\) pH -
\(P_{O_2}\) Oxygen partial pressure (air 0.21 atm) -
\(k\) Rate constant (Stumm and Lee: 8 × 10¹³ L²/(mol²·atm·min) at 20 °C) -
\(Q\) Flow m³/s
\(k_r\) Pseudo-first-order rate constant 1/s
\(\tau_{CMFR}\) Completely mixed reactor detention s
\(V_{CMFR}\) Completely mixed reactor volume m³
\(\tau_{PFR}\) Plug-flow reactor detention s
\(V_{PFR}\) Plug-flow reactor volume m³
\(t_{1/2}\) Half-life of Fe²⁺ s

Method and standards

Stumm–Lee oxygenation kinetics with ideal reactor models.

Where it is used

  • Sizing aeration and detention tanks for groundwater iron removal.
  • Choosing pH adjustment before filters.

Common mistakes

  • Using the rate constant at 20 °C for cold groundwater without testing.
  • Forgetting that organic-bound iron does not follow this law.

Assumptions and limits

  • pH above 5.5, no complexing organics, oxygen in excess.

Questions and answers

Why does pH matter so much?

The rate is second order in hydroxide: from pH 6.5 to 7.5 it rises 100 times.

Why is the plug-flow reactor so much smaller?

A completely mixed tank runs at the low outlet concentration, so its first-order rate is slowest; plug flow uses the full concentration range.

What do the defaults represent?

An illustrative case: pH 6.5 groundwater, 3 to 0.1 mg/L, 2,000 m3/d. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 20-3, eq. 20-5 (Stumm and Lee, 1961) and Example 20-2

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.