FireCADCalc

Horizontal Paddle Wheel Flocculator: Power and Shaft Speed

Water power for a target G and the paddle shaft speed from paddle board area, radii and drag coefficient for a horizontal-shaft paddle wheel flocculator stage.

Inputs

Examples: Same basin, stage 5 at G 20Two boards per arm, 20 ML/d, 3 stages, 25 min, G 50, 20 C

Accepted: 8.64 to 8,640,000 m³/d
Accepted: 1 to 20
Accepted: 1 to 10
Accepted: 1 to 600 min
Accepted: 5 to 200 1/s
Accepted: 1 to 10
Accepted: 1 to 12
Accepted: 0.02 to 1 m
Accepted: 0.1 to 20 m
Accepted: 0 to 10 m
Accepted: 0 to 10 m
Accepted: 0 to 10 m
Accepted: 0.5 to 3
Accepted: 30 to 100 %
Accepted: 0.1 to 5 mPa·s
Accepted: 900 to 1,100 kg/m³

Results

Board velocities are taken at the board centreline (edge radius minus half the width) and reduced by the relative-velocity factor for the water turning with the paddles. Outer board speeds of 0.15–0.6 m/s are usual.

Stage volume208.33m³
Water power for the G109.17W
Board area at each radius3.5640m²
Shaft speed2.0837rpm
Outer board speed0.42004m/s
Gt for this stage4,800.0

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Same basin, stage 5 at G 20. The inputs, in the units selected above:

InputValue
Plant flow150,000 m³/d
Parallel trains2.0000 -
Stages in series per train5.0000 -
Total flocculation time20.000 min
Velocity gradient in this stage20.000 1/s
Paddle wheels on the shaft in the stage2.0000 -
Boards at each radius per wheel (arms)4.0000 -
Board width0.15000 m
Board length2.9700 m
Radius to the outer edge of the inner board0.67000 m
Radius to the outer edge of the middle board (0 = none)1.3300 m
Radius to the outer edge of the outer board (0 = none)2.0000 m
Drag coefficient (1.5 for long boards, l/b > 20 about 1.9)1.5000 -
Paddle velocity relative to the water75.000 %
Water dynamic viscosity (10 °C 1.31 mPa·s, 20 °C 1.00)1.3100 mPa·s
Water density999.70 kg/m³

Applying the formula below gives:

ResultValue
Stage volume208.33 m³
Water power for the G109.17 W
Board area at each radius3.5640 m²
Shaft speed2.0837 rpm
Outer board speed0.42004 m/s
Gt for this stage4,800.0

Open this example in the calculator and change any input.

Formula

\(P = G^2\mu V = \frac{C_DA_p\rho}{2}\sum_i v_{p,i}^3, \quad v_{p,i} = k\,\omega r_i\)

\(N = \frac{60}{2\pi}\left[\frac{2P}{C_DA_p\rho k^3\sum r_i^3}\right]^{1/3}\)

Variables

Symbol Meaning SI unit
\(Q\) Plant flow m³/s
\(n_t\) Parallel trains -
\(n_s\) Stages in series per train -
\(t\) Total flocculation time s
\(G\) Velocity gradient in this stage 1/s
\(n_w\) Paddle wheels on the shaft in the stage -
\(n_a\) Boards at each radius per wheel (arms) -
\(b\) Board width m
\(l\) Board length m
\(r_1\) Radius to the outer edge of the inner board m
\(r_2\) Radius to the outer edge of the middle board (0 = none) m
\(r_3\) Radius to the outer edge of the outer board (0 = none) m
\(C_D\) Drag coefficient (1.5 for long boards, l/b > 20 about 1.9) -
\(k\) Paddle velocity relative to the water -
\(\mu\) Water dynamic viscosity (10 °C 1.31 mPa·s, 20 °C 1.00) Pa·s
\(\rho\) Water density kg/m³
\(V\) Stage volume m³
\(P\) Water power for the G W
\(A_p\) Board area at each radius m²
\(N\) Shaft speed rad/s
\(v_{tip}\) Outer board speed m/s
\(Gt\) Gt for this stage -

Method and standards

Drag power of paddle boards related to the Camp–Stein velocity gradient.

Where it is used

  • Setting variable-speed paddle drives for tapered flocculation.
  • Checking older paddle flocculators.

Common mistakes

  • Using the board edge radius instead of its centreline.
  • Forgetting the relative-velocity factor.

Assumptions and limits

  • Boards at each radius of equal size; drag coefficient from the board aspect ratio.

Questions and answers

Why the 0.75 factor?

The water rotates with the paddles, so the paddle moves through it at roughly 0.6–0.8 of its own speed; 0.75 is customary.

Why limit the paddle area?

Boards should cover no more than about 15–20 % of the swept cross-section, or the water simply rotates with the wheel.

What do the defaults represent?

An illustrative case: Same basin, stage 5 at G 20. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 9-7, eqs. 9-40 and 9-66, Table 9-14 and Example 9-9

Related calculators