Worked example
Example: Same basin, stage 5 at G 20. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Plant flow | 150,000 m³/d |
| Parallel trains | 2.0000 - |
| Stages in series per train | 5.0000 - |
| Total flocculation time | 20.000 min |
| Velocity gradient in this stage | 20.000 1/s |
| Paddle wheels on the shaft in the stage | 2.0000 - |
| Boards at each radius per wheel (arms) | 4.0000 - |
| Board width | 0.15000 m |
| Board length | 2.9700 m |
| Radius to the outer edge of the inner board | 0.67000 m |
| Radius to the outer edge of the middle board (0 = none) | 1.3300 m |
| Radius to the outer edge of the outer board (0 = none) | 2.0000 m |
| Drag coefficient (1.5 for long boards, l/b > 20 about 1.9) | 1.5000 - |
| Paddle velocity relative to the water | 75.000 % |
| Water dynamic viscosity (10 °C 1.31 mPa·s, 20 °C 1.00) | 1.3100 mPa·s |
| Water density | 999.70 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Stage volume | 208.33 m³ |
| Water power for the G | 109.17 W |
| Board area at each radius | 3.5640 m² |
| Shaft speed | 2.0837 rpm |
| Outer board speed | 0.42004 m/s |
| Gt for this stage | 4,800.0 |
Open this example in the calculator and change any input.
Formula
\(P = G^2\mu V = \frac{C_DA_p\rho}{2}\sum_i v_{p,i}^3, \quad v_{p,i} = k\,\omega r_i\)
\(N = \frac{60}{2\pi}\left[\frac{2P}{C_DA_p\rho k^3\sum r_i^3}\right]^{1/3}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Plant flow | m³/s |
| \(n_t\) | Parallel trains | - |
| \(n_s\) | Stages in series per train | - |
| \(t\) | Total flocculation time | s |
| \(G\) | Velocity gradient in this stage | 1/s |
| \(n_w\) | Paddle wheels on the shaft in the stage | - |
| \(n_a\) | Boards at each radius per wheel (arms) | - |
| \(b\) | Board width | m |
| \(l\) | Board length | m |
| \(r_1\) | Radius to the outer edge of the inner board | m |
| \(r_2\) | Radius to the outer edge of the middle board (0 = none) | m |
| \(r_3\) | Radius to the outer edge of the outer board (0 = none) | m |
| \(C_D\) | Drag coefficient (1.5 for long boards, l/b > 20 about 1.9) | - |
| \(k\) | Paddle velocity relative to the water | - |
| \(\mu\) | Water dynamic viscosity (10 °C 1.31 mPa·s, 20 °C 1.00) | Pa·s |
| \(\rho\) | Water density | kg/m³ |
| \(V\) | Stage volume | m³ |
| \(P\) | Water power for the G | W |
| \(A_p\) | Board area at each radius | m² |
| \(N\) | Shaft speed | rad/s |
| \(v_{tip}\) | Outer board speed | m/s |
| \(Gt\) | Gt for this stage | - |
Method and standards
Drag power of paddle boards related to the Camp–Stein velocity gradient.
Where it is used
- Setting variable-speed paddle drives for tapered flocculation.
- Checking older paddle flocculators.
Common mistakes
- Using the board edge radius instead of its centreline.
- Forgetting the relative-velocity factor.
Assumptions and limits
- Boards at each radius of equal size; drag coefficient from the board aspect ratio.
Questions and answers
Why the 0.75 factor?
The water rotates with the paddles, so the paddle moves through it at roughly 0.6–0.8 of its own speed; 0.75 is customary.
Why limit the paddle area?
Boards should cover no more than about 15–20 % of the swept cross-section, or the water simply rotates with the wheel.
What do the defaults represent?
An illustrative case: Same basin, stage 5 at G 20. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 9-7, eqs. 9-40 and 9-66, Table 9-14 and Example 9-9