Worked example
Example: H2S 5 mg/L, 15 m head, 60 deg spray, 2 mm drops. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Water flow | 0.020000 m³/s |
| Head available at the nozzles | 15.000 m |
| Nozzle diameter | 20.000 mm |
| Nozzle discharge coefficient | 30.000 % |
| Nozzle velocity coefficient | 50.000 % |
| Spray angle from horizontal | 60.000 ° |
| Drop (Sauter mean) diameter | 2.0000 mm |
| Liquid diffusivity of the gas | 1.4000e-09 m²/s |
| Dissolved gas in the feed | 5.0000 mg/L |
Applying the formula below gives:
| Result | Value |
|---|---|
| Flow per nozzle | 1.6166 L/s |
| Nozzles required | 13.000 |
| Drop exit velocity | 8.5761 m/s |
| Drop contact time | 1.5147 s |
| Penetration ratio (Higbie valid below 0.22) | 0.046050 |
| Liquid-side mass transfer coefficient | 0.034305 mm/s |
| Specific interfacial area | 3,000.0 1/m |
| Volumetric coefficient | 0.10291 1/s |
| Dissolved gas after spraying | 4.2783 mg/L |
| Removal | 14.434 % |
Open this example in the calculator and change any input.
Formula
\(Q_n = C_dA_n\sqrt{2gh}, \quad v_d = C_v\sqrt{2gh}, \quad t = \frac{2v_d\sin\alpha}{g}\)
\(K_L = 2\left(\frac{D_l}{\pi t}\right)^{1/2}, \quad a = \frac{6}{d_d}, \quad C_e = C_0e^{-K_Lat}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Water flow | m³/s |
| \(h\) | Head available at the nozzles | m |
| \(d_n\) | Nozzle diameter | m |
| \(C_d\) | Nozzle discharge coefficient | - |
| \(C_v\) | Nozzle velocity coefficient | - |
| \(\alpha\) | Spray angle from horizontal | rad |
| \(d_d\) | Drop (Sauter mean) diameter | m |
| \(D_l\) | Liquid diffusivity of the gas | m²/s |
| \(C_0\) | Dissolved gas in the feed | kg/m³ |
| \(Q_n\) | Flow per nozzle | m³/s |
| \(N\) | Nozzles required | - |
| \(v_d\) | Drop exit velocity | m/s |
| \(t\) | Drop contact time | s |
| \(2\sqrt{D_lt}/d_d\) | Penetration ratio (Higbie valid below 0.22) | - |
| \(K_L\) | Liquid-side mass transfer coefficient | m/s |
| \(a\) | Specific interfacial area | 1/m |
| \(K_La\) | Volumetric coefficient | 1/s |
| \(C_e\) | Dissolved gas after spraying | kg/m³ |
| \(R\) | Removal | - |
Method and standards
Penetration-theory mass transfer to free-flying drops.
Where it is used
- CO₂ and H₂S removal from groundwater.
- Decorative fountains doubling as aerators.
Common mistakes
- Forgetting the spray angle in the flight time.
- Using it for low-volatility VOCs.
Assumptions and limits
- Short contact; gas phase concentration negligible.
Questions and answers
Why does the spray angle matter?
A vertical spray gives the longest flight time 2v_d sin α/g, and so the most transfer.
Which gases suit spray aeration?
Highly volatile ones such as carbon dioxide, hydrogen sulfide and radon; for VOCs a packed tower is far more efficient.
What do the defaults represent?
An illustrative case: H2S 5 mg/L, 15 m head, 60 deg spray, 2 mm drops. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 14-8, eqs. 14-70 to 14-76 and Example 14-9