Membrane Specific Flux at 20 °C and Fouling Loss

Temperature-corrected flux and specific flux of a membrane filter at two dates, and the percentage loss of permeability from fouling between them.

Inputs

Examples: Winter 50 LMH, 0.8 bar, 4 C; summer 70 LMH, 0.6 bar, 28 CAfter cleaning: 60 LMH, 0.9 bar, 15 C then 60 LMH, 0.55 bar, 15 C

Accepted: 0.36 to 3,600 L/(m²·h)
Accepted: 0.01 to 100 bar
Accepted: 0 to 50 °C
Accepted: 0.36 to 3,600 L/(m²·h)
Accepted: 0.01 to 100 bar
Accepted: 0 to 50 °C
Accepted: 1 to 1.1
Accepted: 0 to 50 °C

Results

Specific flux is in L/(m²·h·bar) at the standard temperature. The 1.03-per-degree correction follows the viscosity of water; a negative loss means the membrane is cleaner than at date 1.

Flux at standard temperature, date 180.235L/(m²·h)
Specific flux, date 1100.29
Flux at standard temperature, date 255.259L/(m²·h)
Specific flux, date 292.098
Loss of specific flux (fouling)8.1724%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Winter 50 LMH, 0.8 bar, 4 C; summer 70 LMH, 0.6 bar, 28 C. The inputs, in the units selected above:

InputValue
Flux at date 150.000 L/(m²·h)
Transmembrane pressure at date 10.80000 bar
Water temperature at date 14.0000 °C
Flux at date 270.000 L/(m²·h)
Transmembrane pressure at date 20.60000 bar
Water temperature at date 228.000 °C
Temperature correction base (per °C)1.0300 -
Standard temperature20.000 °C

Applying the formula below gives:

ResultValue
Flux at standard temperature, date 180.235 L/(m²·h)
Specific flux, date 1100.29
Flux at standard temperature, date 255.259 L/(m²·h)
Specific flux, date 292.098
Loss of specific flux (fouling)8.1724 %

Open this example in the calculator and change any input.

Formula

\(J_s = J_m\,\theta^{(T_s - T_m)}, \quad J_{sp} = \frac{J_s}{TMP}\)

Variables

Symbol Meaning SI unit
\(J_1\) Flux at date 1 m/s
\(TMP_1\) Transmembrane pressure at date 1 Pa
\(T_1\) Water temperature at date 1 K
\(J_2\) Flux at date 2 m/s
\(TMP_2\) Transmembrane pressure at date 2 Pa
\(T_2\) Water temperature at date 2 K
\(\theta\) Temperature correction base (per °C) -
\(T_s\) Standard temperature K
\(J_{s,1}\) Flux at standard temperature, date 1 m/s
\(J_{sp,1}\) Specific flux, date 1 -
\(J_{s,2}\) Flux at standard temperature, date 2 m/s
\(J_{sp,2}\) Specific flux, date 2 -
\(\Delta J_{sp}\) Loss of specific flux (fouling) -

Method and standards

Empirical viscosity correction and specific flux.

Where it is used

  • Tracking membrane fouling and cleaning effectiveness.
  • Comparing pilot runs at different temperatures.

Common mistakes

  • Comparing raw flux at different temperatures.
  • Using feed pressure instead of transmembrane pressure.

Assumptions and limits

  • Viscosity correction by a constant θ; valid roughly 5–30 °C.

Questions and answers

Why correct to 20 °C?

Water viscosity changes about 3 % per degree; without correction a seasonal temperature swing looks like fouling or cleaning.

When should I clean?

Typically when the specific flux has fallen 20–40 % from its clean value, or the TMP reaches the system's limit.

What do the defaults represent?

An illustrative case: Winter 50 LMH, 0.8 bar, 4 C; summer 70 LMH, 0.6 bar, 28 C. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 12-5, eqs. 12-8 and 12-9 and Example 12-4

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.