Worked example
Example: Full-scale: 2 mg/L chlorine from 120 g/L hypochlorite, Kenics 0.6 m, 0.4 m3/s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Chemical dose | 2.0000 mg/L |
| Strength of the chemical feed | 120.00 g/L |
| Target coefficient of variation | 5.0000 % |
| Mixing device (Godfrey) | Kenics static mixer (0.63, 2.0) |
| Mixer or pipe diameter | 600.00 mm |
| Water flow | 24,000 L/min |
| Length of one mixer insert in diameters (0 for continuous length) | 1.5000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Volume fraction of the feed | 1.6666e-05 |
| Required uniformity ratio | 2.0412e-04 |
| Intensity of segregation | 4.1667e-08 |
| Length-to-diameter ratio required | 18.390 |
| Number of inserts | 13.000 |
| Length-to-diameter ratio provided | 19.500 |
| Mixer length | 11.700 m |
| Velocity | 1.4147 m/s |
| Blending time | 8.2702 s |
| Head loss | 3.9797 m |
Open this example in the calculator and change any input.
Formula
\(X_A = \frac{C_{dose}}{C_A + C_{dose}}, \quad \frac{\sigma_b}{\sigma_u} = \frac{COV\cdot X_A}{\sqrt{X_A(1 - X_A)}}, \quad I_s = \left(\frac{\sigma_b}{\sigma_u}\right)^2\)
\(\frac{L}{D} = \frac{\ln(\sigma_b/\sigma_u)}{\ln(\sigma_b/\sigma_u)_{AR=1}}, \quad H_L = N_{VH}\frac{L}{D}\frac{v^2}{2g}, \quad t_b = \frac{L}{v}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(C_{dose}\) | Chemical dose | kg/m³ |
| \(C_A\) | Strength of the chemical feed | kg/m³ |
| \(COV\) | Target coefficient of variation | - |
| \(\text{device}\) | Mixing device (Godfrey) | - |
| \(D\) | Mixer or pipe diameter | m |
| \(Q\) | Water flow | m³/s |
| \(L_{ins}/D\) | Length of one mixer insert in diameters (0 for continuous length) | - |
| \(X_A\) | Volume fraction of the feed | - |
| \((\sigma_b/\sigma_u)\) | Required uniformity ratio | - |
| \(I_s\) | Intensity of segregation | - |
| \(L/D\) | Length-to-diameter ratio required | - |
| \(n\) | Number of inserts | - |
| \(L/D_{used}\) | Length-to-diameter ratio provided | - |
| \(L\) | Mixer length | m |
| \(v\) | Velocity | m/s |
| \(t_b\) | Blending time | s |
| \(H_L\) | Head loss | m |
Method and standards
Godfrey's exponential decay of segregation with mixer length.
Where it is used
- Coagulant, fluoride and chlorine dosing.
- Locating analyser sample points.
Common mistakes
- Sampling before the chemical is blended.
- Ignoring the head loss of static mixers at full scale.
Assumptions and limits
- Turbulent flow; Godfrey's device constants.
Questions and answers
Why does the feed strength matter?
A strong feed is a tiny volume fraction to spread through the flow; the weaker the starting uniformity, the more mixing length is needed.
Static mixer or empty pipe?
An empty pipe needs about 30 diameters to cut the COV five-fold; a static mixer does it in a few diameters at a higher head loss.
What do the defaults represent?
An illustrative case: Full-scale: 2 mg/L chlorine from 120 g/L hypochlorite, Kenics 0.6 m, 0.4 m3/s. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 6-10, eqs. 6-142 to 6-159, Table 6-8 and Examples 6-11 to 6-13 (Godfrey 1985)