Worked example
Example: 3 m tank, 1 m PBT at 90 rpm. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Impeller power number | 1.2700 - |
| Impeller speed | 90.000 rpm |
| Impeller diameter | 1.0000 m |
| Tank diameter | 3.0000 m |
| Liquid density | 1,000.0 kg/m³ |
| Liquid viscosity | 1.0000 cP |
Applying the formula below gives:
| Result | Value |
|---|---|
| Impeller Reynolds number | 1,500,000 |
| Blend time to 95 % | 28.811 s |
| Power per volume (H = T) | 0.20213 kW/m³ |
Open this example in the calculator and change any input.
Formula
\(\theta_{95} = \frac{5.20}{N\,N_p^{1/3}}\left(\frac{T}{D}\right)^2, \quad Re = \frac{\rho ND^2}{\mu}, \quad \frac{P}{V} = \frac{N_p\rho N^3D^5}{\pi T^3/4}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(N_p\) | Impeller power number | - |
| \(N\) | Impeller speed | 1/s |
| \(D\) | Impeller diameter | m |
| \(T\) | Tank diameter | m |
| \(\rho\) | Liquid density | kg/m³ |
| \(\mu\) | Liquid viscosity | Pa·s |
| \(Re\) | Impeller Reynolds number | - |
| \(\theta_{95}\) | Blend time to 95 % | s |
| \(P/V\) | Power per volume (H = T) | W/m³ |
Method and standards
Grenville's correlation.
Where it is used
- Additive dosing and neutralisation tanks.
- Batch blending specifications.
Common mistakes
- Applying it in laminar or transitional flow.
- Using it for tall tanks with one impeller.
Assumptions and limits
- H ≈ T (the volume for P/V is a cylinder with H = T); baffled; turbulent. The power number is taken as constant, which holds only in turbulent flow; below Re 10 000 the time is shown with a warning and is too short.
- Grenville fitted the correlation over a limited range of D/T; check yours against the Handbook of Industrial Mixing.
References
- Grenville (1992) correlation
- θ₉₅N = 5.20 N_p^(−1/3)(T/D)²
- in Paul
- Atiemo-Obeng and Kresta
- Handbook of Industrial Mixing (Wiley, 2004)
- ch. 9
Questions and answers
Why does a bigger impeller blend faster?
Blend time falls with (D/T)²: a large, slow impeller circulates the whole tank more effectively than a small fast one.
Is blend time the same for all impellers at equal power?
Nearly so in turbulent flow: at equal power per volume and D/T, blend time is almost independent of impeller type.
What do the defaults represent?
A 3 m tank stirred by a 1 m pitched-blade turbine at 90 rpm in water.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.