Worked example
Example: Benzene at 25 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Temperature | 25.000 °C |
| Critical temperature | 288.90 °C |
| Critical pressure | 48.950 bar |
| Rackett parameter (or Z_c) | 0.26980 - |
| Molar mass | 78.114 kg/kmol |
Applying the formula below gives:
| Result | Value |
|---|---|
| Reduced temperature | 0.53047 |
| Saturated liquid molar volume | 89.634 cm³/mol |
| Saturated liquid density | 871.48 kg/m³ |
Open this example in the calculator and change any input.
Formula
\(V_s = \frac{RT_c}{p_c}Z_{RA}^{\,1 + (1 - T_r)^{2/7}}, \quad \rho = \frac{M}{V_s}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T\) | Temperature | K |
| \(T_c\) | Critical temperature | K |
| \(p_c\) | Critical pressure | Pa |
| \(Z_{RA}\) | Rackett parameter (or Z_c) | - |
| \(M\) | Molar mass | kg/kmol |
| \(T_r\) | Reduced temperature | - |
| \(V_s\) | Saturated liquid molar volume | m³/mol |
| \(\rho\) | Saturated liquid density | kg/m³ |
Method and standards
Rackett equation (Spencer–Danner form).
Where it is used
- Process simulation checks.
- Tank and line sizing for organics.
Common mistakes
- Using Z_c of another compound.
- Applying above T_c.
Assumptions and limits
- Saturated liquid; non-polar and slightly polar compounds.
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 2 (physical properties): Rackett equation with the Spencer–Danner parameter Z_RA
Questions and answers
What is Z_RA?
A fitted compressibility close to Z_c; using Z_RA improves accuracy to about 1 %.
Does it give the density of compressed liquid?
No, saturated liquid only; compressed liquids are slightly denser.
What do the defaults represent?
Benzene: T_c 562.05 K, p_c 48.95 bar, Z_RA 0.2698; about 871 kg/m³ at 25 °C.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.