Worked example
Example: To 5 % from 30 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Dry solids | 500.00 kg |
| Drying surface | 25.000 m² |
| Critical moisture (dry basis) | 0.30000 kg/kg |
| Final moisture (dry basis) | 0.050000 kg/kg |
| Equilibrium moisture (dry basis) | 0.020000 kg/kg |
| Constant drying rate | 1.8000 kg/(m²·h) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Falling-rate drying time | 6.9490 h |
| Rate at the end | 0.19286 kg/(m²·h) |
Open this example in the calculator and change any input.
Formula
\(t_f = \frac{m_s(X_c - X^*)}{A N_c}\ln\frac{X_c - X^*}{X_2 - X^*}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(m_s\) | Dry solids | kg |
| \(A\) | Drying surface | m² |
| \(X_c\) | Critical moisture (dry basis) | kg/kg |
| \(X_2\) | Final moisture (dry basis) | kg/kg |
| \(X^*\) | Equilibrium moisture (dry basis) | kg/kg |
| \(N_c\) | Constant drying rate | kg/(m²·s) |
| \(t_f\) | Falling-rate drying time | s |
| \(N_2\) | Rate at the end | kg/(m²·s) |
Method and standards
Integration of a rate linear in free moisture.
Where it is used
- Dryer sizing.
- Estimating time to final moisture.
Common mistakes
- Using X₂ below X*.
- Mixing wet and dry bases.
Assumptions and limits
- Linear falling rate.
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 12 (drying): falling-rate period with rate proportional to free moisture
Questions and answers
Why does the rate fall?
Moisture must move from inside the solid to the surface, which slows as the solid dries.
Why can't I reach X*?
The time grows logarithmically and becomes infinite at the equilibrium moisture.
Is the linear rate exact?
It is the simplest model; measured drying curves are better.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.