Worked example
Example: N2–CO2 50/50 at 300 K. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Mole fraction of gas 1 | 50.000 % |
| Viscosity of gas 1 | 0.017600 cP |
| Viscosity of gas 2 | 0.014700 cP |
| Molar mass of gas 1 | 28.014 kg/kmol |
| Molar mass of gas 2 | 44.009 kg/kmol |
Applying the formula below gives:
| Result | Value |
|---|---|
| Interaction parameter Φ₁₂ | 1.3682 |
| Interaction parameter Φ₂₁ | 0.72743 |
| Mixture viscosity | 0.015942 cP |
Open this example in the calculator and change any input.
Formula
\(\mu_m = \sum_i\frac{y_i\mu_i}{\sum_j y_j\Phi_{ij}}, \quad \Phi_{ij} = \frac{\left[1 + (\mu_i/\mu_j)^{1/2}(M_j/M_i)^{1/4}\right]^2}{\sqrt{8(1 + M_i/M_j)}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(y_1\) | Mole fraction of gas 1 | - |
| \(\mu_1\) | Viscosity of gas 1 | Pa·s |
| \(\mu_2\) | Viscosity of gas 2 | Pa·s |
| \(M_1\) | Molar mass of gas 1 | kg/kmol |
| \(M_2\) | Molar mass of gas 2 | kg/kmol |
| \(\Phi_{12}\) | Interaction parameter Φ₁₂ | - |
| \(\Phi_{21}\) | Interaction parameter Φ₂₁ | - |
| \(\mu_m\) | Mixture viscosity | Pa·s |
Method and standards
Wilke's rule (Φ_ii = 1).
Where it is used
- Flue gas and process gas property estimates.
Common mistakes
- Using at high pressure.
- Mixing mass and mole fractions.
Assumptions and limits
- Low-pressure gases.
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 2 (transport properties): Wilke's mixing rule for low-pressure gas mixtures
Questions and answers
Why not average by mole fraction?
Light, viscous molecules such as hydrogen distort a simple average; Wilke's rule corrects for it.
How accurate is it?
About 1–2 % for non-polar gases at low pressure.
What do the defaults represent?
Nitrogen and CO₂ at about 300 K.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.