FireCADCalc

Adsorber Breakthrough: Length of Unused Bed (LUB)

Breakthrough time of a fixed-bed adsorber of new length from a test bed's breakthrough and stoichiometric times, by the length-of-unused-bed method.

Distillery and ethanolRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 0.5 m test, 3.0/3.6 h; 2 m bedSieve bed

Results

Length of unused bed0.083333m
Front velocity3.8580e-05m/s
Breakthrough time of the design bed13.800h
Bed used at breakthrough95.833%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 0.5 m test, 3.0/3.6 h; 2 m bed. The inputs, in the units selected above:

InputValue
Test bed length0.50000 m
Test breakthrough time3.0000 h
Test stoichiometric (mid-front) time3.6000 h
Design bed length2.0000 m

Applying the formula below gives:

ResultValue
Length of unused bed0.083333 m
Front velocity3.8580e-05 m/s
Breakthrough time of the design bed13.800 h
Bed used at breakthrough95.833 %

Open this example in the calculator and change any input.

Formula

\(LUB = L_t\left(1 - \frac{t_b}{t_s}\right), \quad v_f = \frac{L_t}{t_s}, \quad t_b' = \frac{L - LUB}{v_f}\)

Variables

Symbol Meaning SI unit
\(L_t\) Test bed length m
\(t_b\) Test breakthrough time s
\(t_s\) Test stoichiometric (mid-front) time s
\(L\) Design bed length m
\(LUB\) Length of unused bed m
\(v_f\) Front velocity m/s
\(t_b'\) Breakthrough time of the design bed s
\(1 - LUB/L\) Bed used at breakthrough -

Method and standards

Constant-pattern LUB method.

Where it is used

  • Activated carbon, molecular sieve and ion-exchange bed design.

Common mistakes

  • Scaling with a different superficial velocity.
  • Using the 50 % point for an asymmetric curve.

Assumptions and limits

  • Constant-pattern front; same superficial velocity, particle size and temperature as the test. There is no input for a velocity change: scale the test to the design velocity before using it.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 16 (adsorption): length of unused bed (LUB) scale-up for a constant-pattern front

Questions and answers

What is the stoichiometric time?

The time at which the front's midpoint (or the time equivalent of the area above the curve) reaches the bed end.

Why does the LUB stay constant?

With a favourable isotherm the mass-transfer zone keeps a constant shape as it moves.

When does it fail?

At different velocities, particle sizes or temperatures from the test.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.