Worked example
Example: 2 t/h water, 2.2 MW. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Water evaporated | 2,000.0 kg/h |
| Latent heat of evaporation | 2,330.0 kJ/kg |
| Heat supplied to the dryer | 2,200.0 kW |
| Inlet air temperature | 180.00 °C |
| Exhaust air temperature | 80.000 °C |
| Ambient temperature | 25.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Thermal efficiency | 58.838 % |
| Heat per kg of water evaporated | 3.9600 MJ/kg |
| Adiabatic (ideal) efficiency | 64.516 % |
Open this example in the calculator and change any input.
Formula
\(\eta = \frac{E\lambda}{Q}, \quad \eta_{ad} = \frac{T_1 - T_2}{T_1 - T_0}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(E\) | Water evaporated | kg/s |
| \(\lambda\) | Latent heat of evaporation | J/kg |
| \(Q\) | Heat supplied to the dryer | W |
| \(T_1\) | Inlet air temperature | K |
| \(T_2\) | Exhaust air temperature | K |
| \(T_0\) | Ambient temperature | K |
| \(\eta\) | Thermal efficiency | - |
| \(Q/E\) | Heat per kg of water evaporated | J/kg |
| \(\eta_{ad}\) | Adiabatic (ideal) efficiency | - |
Method and standards
Energy balance definitions.
Where it is used
- Dryer audits.
- Comparing dryer types.
Common mistakes
- Ignoring product sensible heat.
- Using LHV fuel input with HHV efficiencies.
Assumptions and limits
- Steady operation.
- Notes flag the impossible cases: latent heat above the heat supplied, or exhaust colder than ambient.
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 12 (drying): thermal efficiency of convective dryers
Questions and answers
What is a good specific heat use?
Convective dryers use 3–6 MJ per kg of water; latent heat alone is about 2.4.
Why compare with the adiabatic efficiency?
It shows the best possible for the chosen air temperatures, without losses.
Why not exhaust much colder?
Humid exhaust near its dew point condenses in ducts and cyclones.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.