Worked example
Example: Solution 108/100 and 67/60 °C, at 20 kPa. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Water boiling point, reference 1 | 100.00 °C |
| Solution boiling point, reference 1 | 108.00 °C |
| Water boiling point, reference 2 | 60.000 °C |
| Solution boiling point, reference 2 | 67.000 °C |
| New pressure (absolute) | 20.000 kPa |
Applying the formula below gives:
| Result | Value |
|---|---|
| Slope of the Dühring line | 1.0250 |
| Water boiling point at p | 60.059 °C |
| Solution boiling point at p | 67.060 °C |
| Boiling-point rise | 7.0015 K |
Open this example in the calculator and change any input.
Formula
\(T_s = T_{s1} + K(T_w - T_{w1}), \quad K = \frac{T_{s1} - T_{s2}}{T_{w1} - T_{w2}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_{w1}\) | Water boiling point, reference 1 | K |
| \(T_{s1}\) | Solution boiling point, reference 1 | K |
| \(T_{w2}\) | Water boiling point, reference 2 | K |
| \(T_{s2}\) | Solution boiling point, reference 2 | K |
| \(p\) | New pressure (absolute) | Pa |
| \(K\) | Slope of the Dühring line | - |
| \(T_w\) | Water boiling point at p | K |
| \(T_s\) | Solution boiling point at p | K |
| \(BPR\) | Boiling-point rise | K |
Method and standards
Linear Dühring line with IF97 water saturation.
Where it is used
- Multiple-effect evaporator design.
- Caustic, sugar and salt solutions.
Common mistakes
- Using data for another concentration.
- Gauge instead of absolute pressure.
Assumptions and limits
- One fixed concentration.
- Reference points with the solution boiling below water are rejected; a note appears when the water boiling point at p is more than one reference span outside the two references (extrapolation).
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 11 (evaporators): Dühring's rule
- Water saturation temperature from IAPWS-IF97
Questions and answers
What is Dühring's rule?
For a solution of fixed concentration, its boiling point is a straight-line function of water's boiling point at the same pressure.
Why two reference points?
They fix the slope and intercept of the line for that concentration.
Does it hold far outside the data?
Approximately; it is best between the reference pressures.