Worked example
Example: Test 10 kWh/t for 50→5 mm; duty 25→1 mm. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Test: specific energy | 10.000 kWh/t |
| Test: feed size (80 % passing) | 50.000 mm |
| Test: product size (80 % passing) | 5.0000 mm |
| Duty: feed size (80 % passing) | 25.000 mm |
| Duty: product size (80 % passing) | 1.0000 mm |
| Bond work index | 15.000 kWh/t |
| Throughput | 50.000 t/h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Kick's law energy | 13.979 kWh/t |
| Rittinger's law energy | 53.333 kWh/t |
| Bond's law energy | 3.7947 kWh/t |
| Power by Bond's law | 189.74 kW |
Open this example in the calculator and change any input.
Formula
\(E_K = C_K\ln\frac{X_F}{X_P}, \quad E_R = C_R\left(\frac{1}{X_P} - \frac{1}{X_F}\right), \quad E_B = 10E_i\left(\frac{1}{\sqrt{X_P}} - \frac{1}{\sqrt{X_F}}\right)\ (\mu m)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(E_0\) | Test: specific energy | J/kg |
| \(X_{F0}\) | Test: feed size (80 % passing) | m |
| \(X_{P0}\) | Test: product size (80 % passing) | m |
| \(X_F\) | Duty: feed size (80 % passing) | m |
| \(X_P\) | Duty: product size (80 % passing) | m |
| \(E_i\) | Bond work index | J/kg |
| \(\dot m\) | Throughput | kg/s |
| \(E_K\) | Kick's law energy | J/kg |
| \(E_R\) | Rittinger's law energy | J/kg |
| \(E_B\) | Bond's law energy | J/kg |
| \(P_B\) | Power by Bond's law | W |
Method and standards
Walker's general law integrated for n = 1, 2 and 1.5.
Where it is used
- Crusher and mill selection.
- Comparing grinding duties.
Common mistakes
- Mixing mean sizes with 80 % passing sizes.
- Extrapolating far beyond the test duty.
Assumptions and limits
- Same material and machine type as the test.
- Sizes are 80 % passing sizes, as Bond's law requires; use the same basis for the test so the three laws compare.
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 21
- Eqs. (21-120) to (21-123): Kick
- Rittinger and Bond
Questions and answers
Which law should I use?
Kick for coarse crushing, Rittinger for fine grinding, Bond (between them) for most mills.
Why calibrate on a test?
The constants depend on the material and machine; one test at a similar duty fixes them.
What sizes does Bond use?
The 80 % passing sizes in micrometres, with E_i in kWh per short or metric tonne.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.