Worked example
Example: Hammer mill 4 mm to 0.8 mm. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Bond work index (per metric tonne) | 12.000 kWh/t |
| Feed 80 % passing size | 4.0000 mm |
| Product 80 % passing size | 0.80000 mm |
| Throughput | 12.000 t/h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Specific energy | 2.3453 kWh/t |
| Mill power | 28.143 kW |
Open this example in the calculator and change any input.
Formula
\(W = 10\,W_i\left(\frac{1}{\sqrt{P_{80}}} - \frac{1}{\sqrt{F_{80}}}\right)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(W_i\) | Bond work index | J/kg |
| \(F_{80}\) | Feed 80 % passing size | m |
| \(P_{80}\) | Product 80 % passing size | m |
| \(\dot m\) | Throughput | kg/s |
| \(W\) | Specific energy | J/kg |
| \(P\) | Mill power | W |
Method and standards
Bond's law.
Where it is used
- Grain and coal mill sizing.
- Energy audits.
Common mistakes
- Sizes in mm in the formula.
Assumptions and limits
- Sizes in µm.
- The work index is per metric tonne; Bond's original values are per short ton and must be multiplied by 1.1023. The default 12 kWh/t has no particular source; Bond's law was built for ores, so back-calculate the index from your own mill.
References
- Bond (1952) W = 10 W_i (1/√P₈₀ − 1/√F₈₀)
- sizes in µm
Questions and answers
Why the square root?
Bond's third theory makes energy proportional to new crack length, scaling with 1/√size.
Work index for grain?
Not tabulated reliably: back-calculate from a mill's measured power and sizes.
Finer is better?
Finer flour raises starch conversion but costs power and can hamper separation.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.