Worked example
Example: Broken rice 62 % starch. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Starch % grain (as received) | 62.000 % |
| Starch conversion (liquefaction and saccharification) | 96.000 % |
| Fermentation efficiency | 91.000 % |
| Distillation efficiency | 98.500 % |
| Grain processed | 250.00 t/d |
| Ethanol density at 20 °C | 789.24 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Glucose per tonne of grain | 661.33 kg/t |
| Ethanol per tonne of grain | 384.13 L/t |
| Ethanol per day (absolute) | 96.032 kL/d |
Open this example in the calculator and change any input.
Formula
\(G = S \eta_s \frac{M_{C_6H_{12}O_6}}{M_{C_6H_{10}O_5}}, \quad y = G \frac{2 M_{EtOH}}{M_{C_6H_{12}O_6}} \frac{\eta_f \eta_d}{\rho_e}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(S\) | Starch % grain (as received) | - |
| \(\eta_s\) | Starch conversion (liquefaction and saccharification) | - |
| \(\eta_f\) | Fermentation efficiency | - |
| \(\eta_d\) | Distillation efficiency | - |
| \(\dot m_g\) | Grain processed | kg/s |
| \(\rho_e\) | Ethanol density at 20 °C | kg/m³ |
| \(G\) | Glucose per tonne of grain | kg/kg |
| \(y\) | Ethanol per tonne of grain | m³/kg |
| \(\dot V_e\) | Ethanol per day (absolute) | m³/s |
Method and standards
Stoichiometry.
Where it is used
- Grain distillery planning.
- Feedstock comparison.
Common mistakes
- Dry-basis starch used with wet grain.
Assumptions and limits
- Starch fully fermentable after hydrolysis.
References
- Starch hydrolysis (C₆H₁₀O₅)ₙ + n H₂O → n C₆H₁₂O₆ (×1.111) and Gay-Lussac stoichiometry C₆H₁₂O₆ → 2 C₂H₅OH + 2 CO₂ with IUPAC atomic masses; ethanol density 789.24 kg/m³ at 20 °C (OIML R 22)
Questions and answers
Why multiply starch by 1.111?
Hydrolysis adds a water molecule to each anhydroglucose unit: 180.16/162.14.
Typical yields?
Broken rice with about 70 % starch gives roughly 420–460 L/t; maize somewhat less.
Starch basis?
Use starch as received; dry-basis starch needs the moisture.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.