Worked example
Example: 100 KLPD, 30 days. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Production | 100.00 kL/d |
| Days of storage | 30.000 d |
| Ullage (empty share at full) | 5.0000 % |
| One tank, nominal | 1,000.0 m³ |
| Stock temperature | 35.000 °C |
| Cubic expansion coefficient | 1,100.0 µm/(m·K) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Stock to hold | 3,000.0 m³ |
| Nominal tankage | 3,157.9 m³ |
| Tanks | 4.0000 |
| Volume at 20 °C per unit volume at stock temperature | 0.98350 |
Open this example in the calculator and change any input.
Formula
\(V_n = \frac{\dot V t}{1 - u}, \quad N = \lceil V_n / V_{tank} \rceil, \quad \frac{V_{20}}{V_T} = 1 - \beta (T - 20\,^\circ C)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot V\) | Production | m³/s |
| \(t\) | Days of storage | s |
| \(u\) | Ullage (empty share at full) | - |
| \(V_{tank}\) | One tank, nominal | m³ |
| \(T\) | Stock temperature | K |
| \(\beta\) | Cubic expansion coefficient | 1/K |
| \(V_s\) | Stock to hold | m³ |
| \(V_n\) | Nominal tankage | m³ |
| \(N\) | Tanks | - |
| \(V_{20}/V_T\) | Volume at 20 °C per unit volume at stock temperature | - |
Method and standards
Definitions.
Where it is used
- Tank farm sizing.
- Stock reconciliation.
Common mistakes
- Nominal tank volume taken as working volume.
Assumptions and limits
- Linear expansion with the β you enter; the default 1.1 × 10⁻³ /K is a round figure for high-strength ethanol near room temperature, not an official value. The OIML R 22 density formula (used in the steel tank and spirit stock calculators) is more exact; use the official tables for excise.
References
- V = Q t/(1 − u); V₂₀ = V_T [1 − β (T − 20 °C)] (linear expansion)
Questions and answers
Expansion coefficient of ethanol?
About 1.1 × 10⁻³ per K near room temperature.
Why ullage?
Space for expansion and to keep the level below the overflow and vent.
Days of storage?
Set by dispatch schedule and oil-company lifting; 15–30 days is common.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.