FireCADCalc

Stillage Evaporator and DDGS Dryer Balance

Syrup, evaporation and evaporator steam from thin stillage, and DDGS, dryer evaporation and dryer heat from wet cake and syrup (Alcohol Textbook ch. 26).

Distillery and ethanolBoiler

Inputs

Examples: 60 t/h thin stillage, 3.5 economyFour effects, 40 % syrup

Alcohol Textbook: syrup of 25–50 % total solids.
Four effects may approach 6–7.
Up to 31–38 % total solids.
From the dryer maker; depends on dryer type and exhaust recycle. The dryer heat output is on the same basis: fuel heat input (on its heating value) or heat delivered, whichever you enter.

Results

Water removed in the evaporator costs far less than in the dryer: push concentration to the syrup limit (25–28 % with suspended solids, up to 50 % with good clarification).

Syrup12.000t/h
Evaporator evaporation48.000t/h
Evaporator steam13.714t/h
DDGS (cake and syrup dried)13.722t/h
Dryer evaporation23.278t/h
Dryer heat22.631MW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 60 t/h thin stillage, 3.5 economy. The inputs, in the units selected above:

InputValue
Thin stillage to the evaporator60.000 t/h
Total solids in thin stillage6.0000 %
Total solids in syrup30.000 %
Evaporator economy (kg vapour per kg steam)3.5000 -
Wet cake from the centrifuges25.000 t/h
Total solids in wet cake35.000 %
Total solids in DDGS90.000 %
Dryer heat per kg of water evaporated3,500.0 kJ/kg

Applying the formula below gives:

ResultValue
Syrup12.000 t/h
Evaporator evaporation48.000 t/h
Evaporator steam13.714 t/h
DDGS (cake and syrup dried)13.722 t/h
Dryer evaporation23.278 t/h
Dryer heat22.631 MW

Open this example in the calculator and change any input.

Formula

\(\dot m_s = \frac{\dot m_t x_t}{x_s}, \quad E = \dot m_t - \dot m_s, \quad \dot m_D = \frac{\dot m_s x_s + \dot m_c x_c}{x_d}, \quad E_d = \dot m_s + \dot m_c - \dot m_D\)

Variables

Symbol Meaning SI unit
\(\dot m_t\) Thin stillage to the evaporator kg/s
\(x_t\) Total solids in thin stillage -
\(x_s\) Total solids in syrup -
\(\varepsilon\) Evaporator economy (kg vapour per kg steam) -
\(\dot m_c\) Wet cake from the centrifuges kg/s
\(x_c\) Total solids in wet cake -
\(x_d\) Total solids in DDGS -
\(q_d\) Dryer heat per kg of water evaporated J/kg
\(\dot m_s\) Syrup kg/s
\(E\) Evaporator evaporation kg/s
\(\dot m_{st}\) Evaporator steam kg/s
\(\dot m_D\) DDGS (cake and syrup dried) kg/s
\(E_d\) Dryer evaporation kg/s
\(\dot Q_d\) Dryer heat W

Method and standards

Total-solids balance.

Where it is used

  • Dryhouse design.
  • Energy audits of grain distilleries.

Common mistakes

  • Counting backset in the evaporator feed.
  • Mixing dry and wet basis.

Assumptions and limits

  • No solids lost.
  • The dryer heat is on the basis of the heat per kg entered (fuel heat input or heat delivered to the dryer).

References

  • Jacques
  • Lyons and Kelsall (eds.)
  • The Alcohol Textbook
  • 4th ed. (Nottingham University Press, 2003)
  • ch. 26 (Meredith)
  • dryhouse design
  • Total-solids balance

Questions and answers

Why evaporate before drying?

A multiple-effect evaporator removes several kilograms of water per kilogram of steam; a dryer needs more than one kilogram of fuel heat per kilogram of water.

Why does syrup solids content stop at 25–50 %?

Suspended solids and viscosity foul the evaporator tubes; clarified thin stillage goes further.

Is backset counted?

Thin stillage returned as backset never reaches the evaporator; enter only the evaporator feed.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.