FireCADCalc

Molasses Requirement and Storage for a KLPD Distillery

Molasses needed per day and per year of operating days for a distillery capacity and yield, and the molasses tank volume for a number of days at its density.

Sugar mill and cogenerationDistillery and ethanolTank and drum

Inputs

Examples: 100 KLPD at 230 L/t60 KLPD B-heavy

Results

Molasses is stored warm-limited: keep it below about 40 °C to avoid sugar loss and foaming.

Molasses per day434.78t/d
Molasses per year143,478t
Storage volume17,991m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 100 KLPD at 230 L/t. The inputs, in the units selected above:

InputValue
Plant capacity (absolute alcohol)100.00 kL/d
Yield230.00 L/t
Operating days per year330.00 d
Storage days60.000 d
Molasses density1,450.0 kg/m³

Applying the formula below gives:

ResultValue
Molasses per day434.78 t/d
Molasses per year143,478 t
Storage volume17,991 m³

Open this example in the calculator and change any input.

Formula

\(\dot m_M = \frac{\dot V_e}{y}, \quad V = \frac{\dot m_M t_s}{\rho_M}\)

Variables

Symbol Meaning SI unit
\(\dot V_e\) Plant capacity (absolute alcohol) m³/s
\(y\) Yield m³/kg
\(t_o\) Operating days per year s
\(t_s\) Storage days s
\(\rho_M\) Molasses density kg/m³
\(\dot m_M\) Molasses per day kg/s
\(M_a\) Molasses per year kg
\(V\) Storage volume m³

Method and standards

Mass balance.

Where it is used

  • Feedstock planning.
  • Molasses tank sizing.

Common mistakes

  • Bulk litres used for capacity.

Assumptions and limits

  • Steady consumption.
  • The storage volume is the molasses volume only: add ullage, dead volume below the outlet and room for foaming when sizing the tank.

References

  • Mass balance; yield from the molasses yield calculator

Questions and answers

How much molasses for 100 KLPD?

At 230 L/t, about 435 t per day.

Molasses density?

About 1.4–1.5 t/m³ at 85–90 brix.

Why limit storage temperature?

Warm molasses loses sugar to Maillard reactions and can foam over.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.