Worked example
Example: 10 m3 at 2 %, lye. The inputs, in the units selected above:
| Input | Value |
|---|---|
| CIP solution volume per clean | 10.000 m³ |
| Caustic strength of the solution (w/w) | 2.0000 % |
| Solution density | 1,020.0 kg/m³ |
| Caustic purity (flake 0.98, lye 0.48) | 48.000 % |
| Cleans per year | 300.00 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| NaOH (100 %) per clean | 204.00 kg |
| Commercial caustic per clean | 425.00 kg |
| Commercial caustic per year | 127.50 t |
Open this example in the calculator and change any input.
Formula
\(m_{NaOH} = V \rho w, \quad m_p = \frac{m_{NaOH}}{p}, \quad M_a = m_p N\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V\) | CIP solution volume per clean | m³ |
| \(w\) | Caustic strength of the solution (w/w) | - |
| \(\rho\) | Solution density | kg/m³ |
| \(p\) | Caustic purity (flake 0.98, lye 0.48) | - |
| \(N\) | Cleans per year | - |
| \(m_{NaOH}\) | NaOH (100 %) per clean | kg |
| \(m_p\) | Commercial caustic per clean | kg |
| \(M_a\) | Commercial caustic per year | kg |
Method and standards
Mass balance.
Where it is used
- Chemical consumption budgets.
Common mistakes
- Volume % used for w/w.
Assumptions and limits
- Fresh make-up of the whole volume every clean; with caustic recovery enter the top-up volume instead.
References
- Mass balance m = V ρ w / p
Questions and answers
Why clean fermenters?
Bacterial contamination eats sugar and makes acids, cutting yield.
Typical strength?
1–3 % NaOH, hot, then rinse; acid washes remove scale.
Lye or flakes?
Enter the purity of what you buy: 48 % lye or 98 % flakes.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.