Worked example
Example: 100 m3/day, 75 % recovered. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Absolute ethanol produced at 20 °C | 4.1667 m³/h |
| CO₂ recovered | 75.000 % |
| Liquid CO₂ density at storage | 1,030.0 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| CO₂ per kg of ethanol | 0.95528 kg/kg |
| CO₂ per litre of ethanol | 753.95 g/L |
| CO₂ produced | 3.1414 t/h |
| Liquid CO₂ recovered | 2.3561 t/h |
| Liquid CO₂ volume | 2.2875 m³/h |
Open this example in the calculator and change any input.
Formula
\(\frac{m_{CO_2}}{m_e} = \frac{M_{CO_2}}{M_e}, \quad \dot m_{CO_2} = \dot V_e\rho_e\frac{M_{CO_2}}{M_e}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot V_e\) | Absolute ethanol produced at 20 °C | m³/s |
| \(\eta\) | CO₂ recovered | - |
| \(\rho_l\) | Liquid CO₂ density at storage | kg/m³ |
| \(m_{CO_2}/m_e\) | CO₂ per kg of ethanol | kg/kg |
| \(m_{CO_2}/V_e\) | CO₂ per litre of ethanol | kg/m³ |
| \(\dot m_{CO_2}\) | CO₂ produced | kg/s |
| \(\dot m_l\) | Liquid CO₂ recovered | kg/s |
| \(\dot V_l\) | Liquid CO₂ volume | m³/s |
Method and standards
Fermentation stoichiometry.
Where it is used
- CO₂ plant sizing and revenue estimates.
Common mistakes
- Counting CO₂ from respiration during propagation.
Assumptions and limits
- Fermentation CO₂ only, one mole per mole of ethanol. CO₂ from yeast growth and side reactions is not counted, so the real gas flow is somewhat higher.
- Ethanol volume is absolute (pure) ethanol; a bulk rectified-spirit volume would overstate the CO₂.
References
- Gay-Lussac stoichiometry C₆H₁₂O₆ → 2 C₂H₅OH + 2 CO₂ (molar masses from IUPAC)
- OIML R 22: ethanol density 789.24 kg/m³ at 20 °C
Questions and answers
How much CO₂ comes with each litre?
About 0.75 kg: 0.955 kg CO₂ per kg ethanol times 0.789 kg/L.
Why not recover all of it?
Early fermentation gas holds air, and some leaves with beer and at low rates.
Is the CO₂ food grade?
After scrubbing, carbon beds, drying and distillation, yes.