Worked example
Example: 5 t/h milk concentrate 48 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Feed (concentrate) | 5,000.0 kg/h |
| Feed solids | 48.000 % |
| Powder moisture (wet basis) | 3.5000 % |
| Feed temperature | 50.000 °C |
| Air inlet | 200.00 °C |
| Air outlet | 90.000 °C |
| Ambient humidity (kg water per kg dry air) | 10.000 g/kg |
| Heat loss share | 10.000 % |
| Ambient air temperature (to the heater) | 25.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Powder | 2,487.0 kg/h |
| Water evaporated | 2,513.0 kg/h |
| Dry air | 60,953 kg/h |
| Outlet humidity | 51.228 g/kg |
| Heat to the air in the heater | 3,036.5 kW |
| Heat per kg water evaporated | 4.3500 MJ/kg |
Open this example in the calculator and change any input.
Formula
\(P = \frac{F x_F}{1 - w_P}, \quad E = F - P, \quad \dot m_a = \frac{E\,[2501 + 1.88T_2 - 4.187T_F]}{(1 - \varepsilon)(1.006 + 1.88Y_0)(T_1 - T_2)}, \quad Q = \dot m_a(1.006 + 1.88Y_0)(T_1 - T_a)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(F\) | Feed (concentrate) | kg/s |
| \(x_F\) | Feed solids | - |
| \(w_P\) | Powder moisture (wet basis) | - |
| \(T_F\) | Feed temperature | K |
| \(T_1\) | Air inlet | K |
| \(T_2\) | Air outlet | K |
| \(Y_0\) | Ambient humidity (kg water per kg dry air) | kg/kg |
| \(\varepsilon\) | Heat loss share | - |
| \(T_a\) | Ambient air temperature (to the heater) | K |
| \(P\) | Powder | kg/s |
| \(E\) | Water evaporated | kg/s |
| \(\dot m_a\) | Dry air | kg/s |
| \(Y_2\) | Outlet humidity | kg/kg |
| \(Q\) | Heat to the air in the heater | W |
| \(Q/E\) | Heat per kg water evaporated | J/kg |
Method and standards
Solids, water and heat balances on the drying chamber (temperatures in °C in the bracket).
Where it is used
- Dairy and food powder plants.
- Chemical spray drying.
Common mistakes
- Ignoring heat losses.
- Using the wet-basis feed moisture as solids.
Assumptions and limits
- Heat loss as a share of the latent load; air heated from the ambient temperature entered (25 °C by default).
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 12 (spray dryers): mass and heat balances
- Psychrometric enthalpy basis: 2 501 kJ/kg at 0 °C
- vapour 1.88 and dry air 1.006 kJ/(kg·K)
Questions and answers
Why is the outlet temperature so important?
It sets the powder moisture; the inlet–outlet difference sets how much air is needed.
What heat use is typical?
4–5 MJ per kg of water for single-stage spray dryers; two-stage with fluid beds is lower.
Why concentrate the feed first?
An evaporator removes water for a fraction of the dryer's energy.