Worked example
Example: 100 µm sand, 20 % solids. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Particle diameter | 0.10000 mm |
| Particle density | 2,650.0 kg/m³ |
| Fluid density | 998.00 kg/m³ |
| Fluid viscosity | 1.0000 cP |
| Solids volume fraction | 20.000 % |
| Single-particle terminal velocity, if known (0 = Stokes) | 0 m/s |
Applying the formula below gives:
| Result | Value |
|---|---|
| Single-particle (Stokes) velocity | 0.009000 m/s |
| Particle Reynolds number | 0.89823 |
| Richardson–Zaki exponent | 4.4142 |
| Hindered settling velocity | 0.003361 m/s |
Open this example in the calculator and change any input.
Formula
\(u_t = \frac{(\rho_p - \rho_f)g d_p^2}{18\mu}\ \text{(or } u_{t,in}\text{ if entered)}, \quad Re_t = \frac{\rho_f u_t d_p}{\mu}, \quad u = u_t(1 - \phi)^n\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(d_p\) | Particle diameter | m |
| \(\rho_p\) | Particle density | kg/m³ |
| \(\rho_f\) | Fluid density | kg/m³ |
| \(\mu\) | Fluid viscosity | Pa·s |
| \(\phi\) | Solids volume fraction | - |
| \(u_t\) | Single-particle (Stokes) velocity | m/s |
| \(Re_t\) | Particle Reynolds number | - |
| \(n\) | Richardson–Zaki exponent | - |
| \(u\) | Hindered settling velocity | m/s |
| \(u_{t,in}\) | Single-particle terminal velocity, if known (0 = Stokes) | m/s |
| \(g\) | Standard gravity, 9.806 65 | m/s² |
Method and standards
Stokes' law with the Richardson–Zaki correction.
Where it is used
- Thickener and classifier design.
- Fluidised-bed expansion.
Common mistakes
- Using Stokes' law outside Re < 0.3.
- Using volume fraction by mass.
Assumptions and limits
- Uniform spheres.
- Stokes' law is used only while Re_t stays below 1; beyond that the calculation stops unless you enter the single-particle terminal velocity from a drag correlation (for example the particle terminal velocity calculator). The exponent n is then taken at the Re of that velocity.
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 17: Richardson and Zaki
- U/Uᵢ = εⁿ [Trans. Inst. Chem. Eng. 32: 35 (1954)]
- Richardson–Zaki exponent: 4.65 (Re < 0.2)
- 4.4 Re^−0.03 (0.2–1)
- 4.4 Re^−0.1 (1–500)
- 2.4 (> 500)
Questions and answers
Why does a slurry settle slower than one particle?
Displaced fluid flows up between the particles and the suspension's effective density and viscosity rise.
What exponent applies?
4.65 in the Stokes range, falling to 2.4 at high Reynolds numbers.
Does it apply to flocculated slurries?
Poorly; use batch settling tests.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.