Worked example
Example: Co-current, 1.5 MW. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Heat to the solids and water | 1,500.0 kW |
| Volumetric heat transfer coefficient, W/(m³·K) | 150.00 W/m³ |
| Gas in | 400.00 °C |
| Gas out | 110.00 °C |
| Solids in | 25.000 °C |
| Solids out | 90.000 °C |
| Flow arrangement | Co-current |
| Length to diameter ratio | 6.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Log-mean temperature difference | 121.11 K |
| Dryer volume | 82.569 m³ |
| Diameter | 2.5973 m |
| Length | 15.584 m |
Open this example in the calculator and change any input.
Formula
\(\Delta T_{lm} = \frac{\Delta T_1 - \Delta T_2}{\ln(\Delta T_1/\Delta T_2)}, \quad \text{co-current: } \Delta T_1 = T_{g1} - T_{s1},\ \Delta T_2 = T_{g2} - T_{s2}; \quad \text{counter-current: } \Delta T_1 = T_{g1} - T_{s2},\ \Delta T_2 = T_{g2} - T_{s1}\)
\(V = \frac{Q}{U_a\,\Delta T_{lm}}, \quad D = \sqrt[3]{\frac{4V}{\pi(L/D)}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Heat to the solids and water | W |
| \(U_a\) | Volumetric heat transfer coefficient, W/(m³·K) | W/(m³·K) |
| \(T_{g1}\) | Gas in | K |
| \(T_{g2}\) | Gas out | K |
| \(T_{s1}\) | Solids in | K |
| \(T_{s2}\) | Solids out | K |
| \(\text{flow}\) | Flow arrangement | - |
| \(L/D\) | Length to diameter ratio | - |
| \(\Delta T_{lm}\) | Log-mean temperature difference | K |
| \(V\) | Dryer volume | m³ |
| \(D\) | Diameter | m |
| \(L\) | Length | m |
Method and standards
Volumetric heat transfer design.
Where it is used
- Rotary dryer and cooler sizing.
Common mistakes
- Using an area U for U_a.
- A temperature cross in co-current flow.
Assumptions and limits
- Uniform U_a; ΔT_lm between gas and solids.
- U_a is entered in W/(m³·K) in every unit system (no per-degree volumetric quantity exists for automatic conversion); 1 Btu/(h·ft³·°F) = 18.63 W/(m³·K).
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 12 (rotary dryers): Q = U_a V ΔT_lm
Questions and answers
Where does U_a come from?
Correlations in gas mass velocity and diameter, or vendor and pilot data; typical values are 100–400 W/(m³·K).
Co-current or counter-current?
Co-current suits heat-sensitive products; counter-current gives a larger mean ΔT.
Why an L/D?
Rotary dryers are usually 4–10 diameters long.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.