Worked example
Example: 40 t/h, 50 to 42 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Wet bagasse | 40.000 t/h |
| Moisture in | 50.000 % |
| Moisture out | 42.000 % |
| Ash % bagasse (wet) | 2.5000 % |
| Brix % bagasse (wet) | 2.0000 % |
| Flue gas through the dryer | 160.00 t/h |
| Flue gas specific heat | 1.1000 kJ/(kg·K) |
| Flue gas in | 200.00 °C |
| Bagasse temperature in | 35.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Water evaporated | 5.5172 t/h |
| Heat taken from the gas | 3,936.7 kW |
| Flue gas out | 119.48 °C |
| Bagasse NCV before drying | 7,375.0 kJ/kg |
| Bagasse NCV after drying | 8,947.6 kJ/kg |
Open this example in the calculator and change any input.
Formula
\(\dot m_v = \dot m_b - \frac{\dot m_b (1 - W_1)}{1 - W_2}, \quad \dot Q = \dot m_v [h_v(T_{g,out}) - h_l(T_b)], \quad T_{g,out} = T_{g,in} - \frac{\dot Q}{\dot m_g c_{p,g}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_b\) | Wet bagasse | kg/s |
| \(W_1\) | Moisture in | - |
| \(W_2\) | Moisture out | - |
| \(A\) | Ash % bagasse (wet) | - |
| \(B_x\) | Brix % bagasse (wet) | - |
| \(\dot m_g\) | Flue gas through the dryer | kg/s |
| \(c_{p,g}\) | Flue gas specific heat | J/(kg·K) |
| \(T_{g,in}\) | Flue gas in | K |
| \(T_b\) | Bagasse temperature in | K |
| \(\dot m_v\) | Water evaporated | kg/s |
| \(\dot Q\) | Heat taken from the gas | W |
| \(T_{g,out}\) | Flue gas out | K |
| \(NCV_1\) | Bagasse NCV before drying | J/kg |
| \(NCV_2\) | Bagasse NCV after drying | J/kg |
Method and standards
Mass balance of the water removed and an energy balance on the gas: the heat taken is the water evaporated from liquid at the bagasse temperature to vapour at the gas exit temperature (IAPWS-IF97 at 1 atm), solved by a short fixed-point iteration. Bagasse NCV by the sugar-industry equation, with ash and brix concentrating as water leaves.
Where it is used
- Bagasse dryer studies.
- Retrofits to raise steam per tonne of bagasse.
Common mistakes
- Wet and dry basis mixed.
- Exit gas below dew point.
Assumptions and limits
- Adiabatic dryer.
- The sensible heat to warm the dry bagasse and the water left in it is not included, so the heat taken and the gas temperature drop are slightly understated.
- The gas dew point is not calculated; the page stops only if the gas would leave below about 60 °C. Check the exit against the dew point of your flue gas.
References
- Mass balance; energy balance with IAPWS-IF97 enthalpies; bagasse NCV by the sugar-industry equation
Questions and answers
Why dry bagasse with flue gas?
Stack heat below the air heater is otherwise lost; drier bagasse burns hotter and raises steam per tonne.
Where does the dryer sit?
After the air heater or economiser, before the dust collector.
Fire risk?
Dry fines and hot gas: dryers need spark detection and quench.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.