Worked example
Example: Massecuite pump 40 rpm. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Body diameter | 0.40000 m |
| Rotor section | 0.060000 m² |
| Barrel width | 0.30000 m |
| Rotor speed | 40.000 rpm |
| Volumetric efficiency | 65.000 % |
| Density of the product | 1,480.0 kg/m³ |
| Total head with losses | 20.000 m |
| Pump efficiency | 65.000 % |
| Reducer and transmission efficiency | 92.000 % |
| Motor efficiency | 85.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Output | 30.731 m³/h |
| Motor input power | 4.8748 kW |
Open this example in the calculator and change any input.
Formula
\(Q = \left(\frac{\pi D^2}{4} - s\right)L\,n\,\rho_v, \quad P = \frac{Q\,d\,g(H + h)}{\rho_m\rho_r\rho_M}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(D\) | Body diameter | m |
| \(s\) | Rotor section | m² |
| \(L\) | Barrel width | m |
| \(n\) | Rotor speed | 1/s |
| \(\rho_v\) | Volumetric efficiency | - |
| \(d\) | Density of the product | kg/m³ |
| \(H + h\) | Total head with losses | m |
| \(\rho_m\) | Pump efficiency | - |
| \(\rho_r\) | Reducer and transmission efficiency | - |
| \(\rho_M\) | Motor efficiency | - |
| \(Q\) | Output | m³/s |
| \(P\) | Motor input power | W |
Method and standards
Hugot's displacement and power.
Where it is used
- Selecting massecuite and molasses pumps.
- Checking motor sizes.
Common mistakes
- Using the body volume without the rotor.
- Neglecting the large friction head of viscous products.
Assumptions and limits
- Positive-displacement pump; head includes pipe losses, which the user must find for the viscous product.
- The rotor speed is compared with Hugot's overall ranges (30–150 rpm); check it against the range for the product.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 44
- rotary pumps
- eqns 44.2–44.3
- pp. 1108–1112
Questions and answers
Why rotary pumps for massecuite?
They move viscous massecuite slowly without crushing crystals.
Why so slow?
Viscous products fill the chambers only at low speed; massecuite pumps run at 30–60 rpm.
Reducer efficiency?
0.90–0.95 for two-stage gearing, only 0.50–0.60 with a worm.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.