Worked example
Example: 50 t/h, 3-circuit boiler. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Steam | 50.000 t/h |
| Steam pressure (absolute) | 28.439 bar |
| Steam temperature | 380.00 °C |
| Feed water temperature | 90.000 °C |
| Standard (French) evaporation rate | 32.000 kg/(m²·h) |
| Steam per kg bagasse | 2.2000 - |
| Net calorific value of the bagasse | 1,900.0 kcal/kg |
| Furnace heat release per m³ | 232.60 kW/m³ |
| Grate loading | 800.00 kg/(m²·h) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heat per kg of steam | 2,809.6 kJ/kg |
| Actual evaporation rate | 30.471 kg/(m²·h) |
| Heating surface | 1,640.9 m² |
| Bagasse fired | 22.727 t/h |
| Furnace volume | 215.91 m³ |
| Grate area | 28.409 m² |
| Heating surface per grate area | 57.760 |
Open this example in the calculator and change any input.
Formula
\(\tau = \tau_0\frac{639}{h}, \quad S = \frac{Q}{\tau}, \quad B = \frac{Q}{r}, \quad V = \frac{BN}{q_v}, \quad s_g = \frac{B}{\beta}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Steam | kg/s |
| \(p_s\) | Steam pressure (absolute) | Pa |
| \(T_s\) | Steam temperature | K |
| \(t_f\) | Feed water temperature | K |
| \(\tau_0\) | Standard (French) evaporation rate | kg/(m²·s) |
| \(r\) | Steam per kg bagasse | - |
| \(N\) | Net calorific value of the bagasse | J/kg |
| \(q_v\) | Furnace heat release per m³ | W/m³ |
| \(\beta\) | Grate loading | kg/(m²·s) |
| \(h\) | Heat per kg of steam | J/kg |
| \(\tau\) | Actual evaporation rate | kg/(m²·s) |
| \(S\) | Heating surface | m² |
| \(B\) | Bagasse fired | kg/s |
| \(V\) | Furnace volume | m³ |
| \(s_g\) | Grate area | m² |
| \(S/s_g\) | Heating surface per grate area | - |
Method and standards
Hugot's sizing rules.
Where it is used
- First sizing of bagasse boilers.
- Checking boiler offers.
Common mistakes
- Mixing French and English standard evaporation.
- Using GCV in the furnace volume.
Assumptions and limits
- Hugot's practice figures.
- The furnace heat release must be on the NCV basis, like the NCV entered; convert GCV-based figures first.
- Steam superheated (or dry) and feed water liquid and colder; otherwise the page stops.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 41
- eqns 41.53–41.60 and Tables 41.23–41.24
- pp. 944–958
- Steam and feed enthalpies from IAPWS-IF97
Questions and answers
What is standard evaporation?
The evaporation per m² converted to a reference heat of 639 kcal per kg (French) or 539 (English), so boilers at different conditions compare.
Why is the furnace volume large for bagasse?
Wet bagasse burns partly in suspension and needs time and space.
Grate loading?
Hugot: step grates 500–1000 kg/(m²·h), horseshoe furnaces 1300–1800, spreaders designed near 800.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.