Bagasse Boiler Efficiency and Steam per kg (Hugot)

Flue gas loss, heat to steam, efficiency on GCV and steam per kg of bagasse (Hugot eqns 41.48–41.51, IF97) from moisture, sugar and excess air.

Sugar mill and cogenerationIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: Hugot example: 28 kg/cm2 g 380 °C, feed 90High pressure, flue 156 °C

Hugot: α 0.975–0.98, β 0.97–0.995, η 0.96–0.99; his example 0.97³ = 0.913.

Results

Hugot's example: 48 % moisture, 2 % sugar, m = 1.4, gas at 200 °C and 0.97³ give about 1 470 kcal/kg to steam and 2.19 kg of steam per kg bagasse at 28 kg/cm² g, 380 °C, feed 90 °C.

Net calorific value7,946.5kJ/kg
Gross calorific value 4600 − 12s − 46w9,914.3kJ/kg
Flue gas loss1,215.5kJ/kg
Heat to steam per kg bagasse6,143.4kJ/kg
Efficiency on GCV61.965%
Heat per kg of steam2,809.6kJ/kg
Steam per kg bagasse2.1866

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Hugot example: 28 kg/cm2 g 380 °C, feed 90. The inputs, in the units selected above:

InputValue
Bagasse moisture48.000 %
Sugar in bagasse2.0000 %
Air factor1.4000 -
Flue gas temperature200.00 °C
Product of combustion, radiation and heat-loss factors91.267 %
Steam pressure (absolute)28.439 bar
Steam temperature380.00 °C
Feed water temperature90.000 °C

Applying the formula below gives:

ResultValue
Net calorific value7,946.5 kJ/kg
Gross calorific value 4600 − 12s − 46w9,914.3 kJ/kg
Flue gas loss1,215.5 kJ/kg
Heat to steam per kg bagasse6,143.2 kJ/kg
Efficiency on GCV61.963 %
Heat per kg of steam2,809.6 kJ/kg
Steam per kg bagasse2.1865

Open this example in the calculator and change any input.

Formula

\(q = [(1 - w)(1.4m - 0.13) + 0.5]t, \quad M_v = (4250 - 4850w - 1200s - q)\alpha\beta\eta\ [\mathrm{kcal/kg}]\)

\(\rho = \frac{M_v}{4600 - 12s - 46w}, \quad \frac{S}{B} = \frac{M_v}{h_s - h_f}\)

Variables

Symbol Meaning SI unit
\(w\) Bagasse moisture -
\(s\) Sugar in bagasse -
\(m\) Air factor -
\(t\) Flue gas temperature K
\(\alpha\beta\eta\) Product of combustion, radiation and heat-loss factors -
\(p_s\) Steam pressure (absolute) Pa
\(T_s\) Steam temperature K
\(t_f\) Feed water temperature K
\(N\) Net calorific value J/kg
\(G\) Gross calorific value 4600 − 12s − 46w J/kg
\(q\) Flue gas loss J/kg
\(M_v\) Heat to steam per kg bagasse J/kg
\(\rho\) Efficiency on GCV -
\(\Delta h\) Heat per kg of steam J/kg
\(S/B\) Steam per kg bagasse -

Method and standards

Hugot's indirect method with IF97 steam enthalpies (s, w in % in the GCV form).

Where it is used

  • Bagasse boiler performance checks.
  • Steam balance planning.

Common mistakes

  • Using GCV-based efficiency with NCV heat.
  • Feed temperature after the economiser vs before.

Assumptions and limits

  • Hugot's average bagasse composition; his GCV and NCV correlations ignore ash and suit normal cane bagasse (moisture about 40–55 %). The flue gas loss is referred to 0 °C as in Hugot.
  • M_v uses the NCV, while the efficiency divides it by the GCV, as Hugot defines it.
  • The steam must be superheated (or dry) and the feed water liquid; otherwise the page stops.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 41
  • eqns 41.20
  • 41.25 and 41.48–41.51 and Table 41.22
  • pp. 913–916 and 932–935
  • Steam and feed enthalpies from IAPWS-IF97

Questions and answers

Why is efficiency on GCV only 50–65 %?

The water in bagasse and from its hydrogen leaves as vapour, so the latent heat in the GCV is never recovered.

What does 1.4m − 0.13 mean?

Hugot's flue gas heat per °C per kg of dry bagasse at air factor m.

Typical steam per kg?

Hugot: 2–2.7, often about 2.25 kg of steam per kg of bagasse.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.