Worked example
Example: Hugot economiser example. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Heat recovery | Economiser (feed water) |
| Flue gas | 121,900 kg/h |
| Gas specific heat | 1.1932 kJ/(kg·K) |
| Gas entering | 350.00 °C |
| Heat retained (losses) | 95.000 % |
| Water or air flow | 50,000 kg/h |
| Its specific heat | 4.1868 kJ/(kg·K) |
| Water or air entering | 90.000 °C |
| Water or air leaving | 165.00 °C |
| Heat-transfer coefficient | 29.075 W/(m²·K) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Ratio αPC/(pc) | 0.66009 |
| Heat recovered | 4,361.3 kW |
| Gas leaving | 236.38 °C |
| Surface | 909.44 m² |
Open this example in the calculator and change any input.
Formula
\(r = \frac{\alpha P C}{p c}, \quad T = T_0 - \frac{t - t_0}{r}, \quad S = \frac{\alpha P C}{k(1 - r)}\ln\frac{T_0 - t}{T - t_0}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{type}\) | Heat recovery | - |
| \(P\) | Flue gas | kg/s |
| \(C\) | Gas specific heat | J/(kg·K) |
| \(T_0\) | Gas entering | K |
| \(\alpha\) | Heat retained (losses) | - |
| \(p\) | Water or air flow | kg/s |
| \(c\) | Its specific heat | J/(kg·K) |
| \(t_0\) | Water or air entering | K |
| \(t\) | Water or air leaving | K |
| \(k\) | Heat-transfer coefficient | W/(m²·K) |
| \(r\) | Ratio αPC/(pc) | - |
| \(\dot Q\) | Heat recovered | W |
| \(T\) | Gas leaving | K |
| \(S\) | Surface | m² |
Method and standards
Hugot's counter-current heat balance.
Where it is used
- Choosing heat recovery for bagasse boilers.
- Checking quotations.
Common mistakes
- Using the gas flow of a different load.
- Water too close to saturation in the economiser.
Assumptions and limits
- Counter-current flow; constant specific heats. Hugot's gas specific heat rises with temperature (0.27 + 0.00006 T kcal/(kg·°C)); enter its value at the mean gas temperature.
- The type choice only selects the notes; the same counter-current formula serves both. The economiser's 30 °C margin below saturation is not checked.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 41
- economisers and air heaters
- eqns 41.68–41.76 and examples
- pp. 975–988
Questions and answers
Economiser or air heater?
Hugot favours the air heater for wet bagasse: hot air dries the fuel and raises the furnace temperature; an economiser suits drier fuel and high pressures.
What is r?
The ratio of the heat capacities of gas and heated fluid; r < 1 for economisers, about 1.2–1.6 for air heaters.
Why a single formula?
Both are counter-current exchangers; Hugot's two forms are the same expression.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.