Worked example
Example: Illustrative: 8 lamps of 10 kW at 15 %, 1.5 m3 as 5 tanks, eps 1650, Phi 0.3, k' 0.25/cm, 50 to 5 ng/L. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Number of lamps | 8.0000 - |
| Electrical power per lamp | 10.000 kW |
| Lamp efficiency to UV at the working wavelength | 15.000 % |
| Wavelength | 254.00 nm |
| Reactor water volume | 1,500.0 L |
| Molar absorption coefficient of the target (decadic) | 1,650.0 - |
| Quantum yield, mol/einstein | 0.30000 - |
| Water absorption coefficient (natural-log basis) | 0.25000 1/cm |
| Equivalent tanks in series | 5.0000 - |
| Influent concentration | 0.050000 ng/L |
| Target effluent concentration | 0.005000 ng/L |
Applying the formula below gives:
| Result | Value |
|---|---|
| Photon flux per volume, einstein/(L·s) | 1.6986e-05 |
| Photolysis rate constant | 0.077442 1/s |
| Hydraulic residence time needed | 37.763 s |
| Flow that can be treated | 39.721 L/s |
| Electrical energy per order | 0.55946 kWh/m³ |
| Orders of removal | 1.0000 |
Open this example in the calculator and change any input.
Formula
\(P_{UV} = \frac{n_lP_l\eta_{UV}\lambda}{hcN_AV}, \quad k = \frac{\Phi P_{UV}\,2.303\,\varepsilon}{k'}\)
\(\tau = \frac{n}{k}\left[\left(\frac{C_0}{C_e}\right)^{1/n} - 1\right], \quad Q = \frac{V}{\tau}, \quad EE/O = \frac{n_lP_l}{Q\log(C_0/C_e)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(n_l\) | Number of lamps | - |
| \(P_l\) | Electrical power per lamp | W |
| \(\eta_{UV}\) | Lamp efficiency to UV at the working wavelength | - |
| \(\lambda\) | Wavelength | m |
| \(V\) | Reactor water volume | m³ |
| \(\varepsilon\) | Molar absorption coefficient of the target (decadic) | - |
| \(\Phi\) | Quantum yield, mol/einstein | - |
| \(k'\) | Water absorption coefficient (natural-log basis) | 1/m |
| \(n\) | Equivalent tanks in series | - |
| \(C_0\) | Influent concentration | kg/m³ |
| \(C_e\) | Target effluent concentration | kg/m³ |
| \(P_{UV}\) | Photon flux per volume, einstein/(L·s) | - |
| \(k\) | Photolysis rate constant | 1/s |
| \(\tau\) | Hydraulic residence time needed | s |
| \(Q\) | Flow that can be treated | m³/s |
| \(EE/O\) | Electrical energy per order | J/m³ |
| \(\log(C_0/C_e)\) | Orders of removal | - |
Method and standards
Direct photolysis kinetics with photon balance and tanks-in-series flow.
Where it is used
- NDMA and other photolabile micropollutant removal.
- Comparing UV reactor offers.
Common mistakes
- Using the decadic ε where the natural-log ε' is needed.
- Ignoring lamp efficiency (only 15–30 % of power is UV-C).
Assumptions and limits
- Monochromatic light; no wall or sleeve losses; optically thick.
References
- Photolysis rate in optically thick water k = Φ P_UV 2.303ε/k' with tanks-in-series hydraulics
Questions and answers
Why does the water's absorbance matter?
In optically thick water the water absorbs almost all the UV; the target's share is its absorbance divided by the water's, so a cleaner water speeds removal.
Why tanks in series?
A real reactor lies between plug flow and full mixing; the tracer-derived number of tanks sets how much residence time a given removal needs.
What do the defaults represent?
An illustrative reactor: 8 lamps of 10 kW at 15 % UV efficiency, 1.5 m³ of water behaving as 5 tanks, a target with ε 1650 L/(mol·cm) and Φ 0.3, water k' 0.25/cm, 50 to 5 ng/L.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 8-4, eqs. 8-115 to 8-126 and Example 8-13