Worked example
Example: Illustrative bench test: 0.12 mW/cm2 for 25 s, 12 mm sample, absorbance 0.08/cm, lamp at 45 cm. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Irradiance at the sample surface centre | 0.12000 mW/cm² |
| Exposure time | 25.000 s |
| Reflection at the water surface | 2.5000 % |
| Petri factor (radiometer map average) | 92.000 % |
| Absorbance coefficient at 254 nm (base 10) | 0.080000 1/cm |
| Sample depth | 12.000 mm |
| Lamp-to-sample-surface distance | 0.45000 m |
| Uncertainty of E_s | 5.0000 % |
| Uncertainty of t | 0.30000 s |
| Uncertainty of P_f | 2.0000 % |
| Uncertainty of a_254 | 0.005000 1/cm |
| Uncertainty of d | 0.50000 mm |
| Uncertainty of L | 5.0000 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Water factor (1 − 10^(−ad))/(2.303 a d) | 89.719 % |
| Divergence factor L/(L + d) | 97.403 % |
| Average UV dose | 2.3516 mJ/cm² |
| Best-estimate uncertainty of the dose | 0.13285 mJ/cm² |
| Relative uncertainty | 5.6492 % |
| Conservative dose | 2.2188 mJ/cm² |
Open this example in the calculator and change any input.
Formula
\(D_{CB} = E_s\,t\,(1 - R)\,P_f\,\frac{1 - 10^{-a_{254}d}}{2.303\,a_{254}d}\,\frac{L}{L + d}\)
\(U_D = \left[\sum_n\left(\frac{\partial D}{\partial V_n}U_{V_n}\right)^2\right]^{1/2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(E_s\) | Irradiance at the sample surface centre | W/m² |
| \(t\) | Exposure time | s |
| \(R\) | Reflection at the water surface | - |
| \(P_f\) | Petri factor (radiometer map average) | - |
| \(a_{254}\) | Absorbance coefficient at 254 nm (base 10) | 1/m |
| \(d\) | Sample depth | m |
| \(L\) | Lamp-to-sample-surface distance | m |
| \(\delta E_s\) | Uncertainty of E_s | - |
| \(\delta t\) | Uncertainty of t | s |
| \(\delta P_f\) | Uncertainty of P_f | - |
| \(\delta a\) | Uncertainty of a_254 | 1/m |
| \(\delta d\) | Uncertainty of d | m |
| \(\delta L\) | Uncertainty of L | m |
| \(WF\) | Water factor (1 − 10^(−ad))/(2.303 a d) | - |
| \(DF\) | Divergence factor L/(L + d) | - |
| \(D_{CB}\) | Average UV dose | J/m² |
| \(U_D\) | Best-estimate uncertainty of the dose | J/m² |
| \(U_D/D\) | Relative uncertainty | - |
| \(D - U_D\) | Conservative dose | J/m² |
Method and standards
Average fluence in a stirred, collimated-beam sample with first-order error propagation.
Where it is used
- UV dose–response tests for reactor validation.
- Biodosimetry with MS2 or other surrogates.
Common mistakes
- Using the decadic absorbance as a natural-log coefficient.
- Skipping the Petri factor.
Assumptions and limits
- Stirred sample; collimated low-pressure lamp at 254 nm.
References
- Collimated-beam dose D = E_s t (1 − R) P_f (1 − 10^(−ad))/(2.303 ad) × L/(L + d) with root-sum-square uncertainty
Questions and answers
Why the water factor?
The sample absorbs UV with depth, so the average irradiance through the stirred depth is below the surface value by (1 − 10^(−ad))/(2.303ad).
Which uncertainty dominates?
Usually the radiometer (about 5 %), then the Petri factor and the timing.
What do the defaults represent?
An illustrative bench test: 0.12 mW/cm² for 25 s, 12 mm of water with an absorbance of 0.08/cm (8 /m), lamp 45 cm above the sample.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 13-9, eqs. 13-63 to 13-66 and Example 13-11