Worked example
Example: Lead element 30 LMH at 0.10 m/s, NaCl 2,000 mg/L (D 1.5e-9). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Feed channel velocity | 0.10000 m/s |
| Feed channel height (spacer) | 0.71000 mm |
| Permeate flux | 30.000 L/(m²·h) |
| Bulk solute concentration | 2,000.0 mg/L |
| Solute diffusivity in water | 1.5000e-09 m²/s |
| Correlation coefficient | 0.47000 - |
| Water density | 998.00 kg/m³ |
| Water viscosity | 1.0000 mPa·s |
Applying the formula below gives:
| Result | Value |
|---|---|
| Hydraulic diameter (2h) | 1.4200 mm |
| Reynolds number | 141.72 |
| Schmidt number | 668.00 |
| Mass transfer coefficient | 0.051666 mm/s |
| Concentration polarisation factor | 1.1750 |
| Concentration at the membrane surface | 2,350.1 mg/L |
Open this example in the calculator and change any input.
Formula
\(Re = \frac{\rho vd_H}{\mu}, \quad Sc = \frac{\mu}{\rho D_L}, \quad k_{CP} = a\frac{D_L}{d_H}Re^{0.5}Sc^{1/3}\)
\(\beta = \frac{C_M}{C_F} = \exp\left(\frac{J_w}{k_{CP}}\right)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(v\) | Feed channel velocity | m/s |
| \(h\) | Feed channel height (spacer) | m |
| \(J_w\) | Permeate flux | m/s |
| \(C_F\) | Bulk solute concentration | kg/m³ |
| \(D_L\) | Solute diffusivity in water | m²/s |
| \(a\) | Correlation coefficient | - |
| \(\rho\) | Water density | kg/m³ |
| \(\mu\) | Water viscosity | Pa·s |
| \(d_H\) | Hydraulic diameter (2h) | m |
| \(Re\) | Reynolds number | - |
| \(Sc\) | Schmidt number | - |
| \(k_{CP}\) | Mass transfer coefficient | m/s |
| \(\beta\) | Concentration polarisation factor | - |
| \(C_M\) | Concentration at the membrane surface | kg/m³ |
Method and standards
Film theory of concentration polarisation with a spacer-channel mass transfer correlation.
Where it is used
- Checking element flux limits.
- Scaling risk at the membrane surface.
Common mistakes
- Using the channel height instead of 2h as the hydraulic diameter.
- Ignoring polarisation when computing osmotic pressure.
Assumptions and limits
Questions and answers
Why does polarisation matter?
The higher wall concentration raises osmotic pressure (cutting flux), raises salt passage and brings sparingly soluble salts closer to scaling.
How do I reduce it?
Lower flux or higher cross-flow velocity; lead elements with high flux are the most affected.
What do the defaults represent?
An illustrative case: Lead element 30 LMH at 0.10 m/s, NaCl 2,000 mg/L (D 1.5e-9). Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 17-5, eqs. 17-33, 17-35 and 17-37 to 17-41 and Example 17-3